title: "JELD-WEN Siteline Clad Wood (W-5500) Casement Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-w-5500-casement-413380/
description: "JELD-WEN Siteline Clad Wood (W-5500) Casement (JEL-N-877, Casement Windows, Wood): U-Factor 0.17-0.32, SHGC 0.00-0.44, 9709 options across 4 ENERGY STAR."
---

Window · Wood Frame NFRC JEL · Product Line JEL-N-877 ENERGY STAR Most Efficient Eligible

# JELD-WEN, inc. — Siteline Clad Wood (W-5500) Casement · Casement Windows

JELD-WEN, inc. engineered the Siteline Clad Wood (W-5500) Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 9,709 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.00 to 0.44 SHGC. Relative to other Wood models tracked under NFRC JEL, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.00-0.44

- **Certified Options** : 9,709

- **Category Standing** : #362 of 1,352

## How does JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement compare thermally against Window peers?

JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Siteline Clad Wood (W-5500) Casement is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 458 configurations meet ENERGY STAR Most Efficient criteria while 468 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-10-09.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 9,709 certified glazing combinations for Siteline Clad Wood (W-5500) Casement (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 468 packages (189 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,232 packages (327 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 4,722 packages (183 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 9,249 packages (314 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Ultimate Outswing French Door Transom G2](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-outswing-french-door-transom-g2-413647/) | Wood | 0.17 | 0.10 | 7,857 |
| [**Andersen Corporation** — 400 Series Specialty Window - Casement Half Circle](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-window-casement-half-circl/) | Wood | 0.17 | 0.15 | 5,280 |
| [**Ply Gem Window Group** — Mira (2018) Casement Stationary](https://ela-ecolandscapingassn.org/windows/models/ply-gem-window-group-mira-2018-casement-stationary-413969/) | Wood | 0.17 | 0.12 | 14,893 |
| [**Weather Shield Mfg., Inc.** — 8312 Flush Frame Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/) | Wood | 0.17 | 0.13 | 4,388 |
| [**Andersen Corporation** — 400 Series Specialty Window - Double Hung Half Circle](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-window-double-hung-half-ci/) | Wood | 0.17 | 0.15 | 2,938 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement appear below.

### What thermal performance numbers separate JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement from peers?

JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement spans 9,709 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.00 to 0.44. Ranked #362 of 1,352 Window families, it carries 458 Most Efficient options.

### Is Siteline Clad Wood (W-5500) Casement approved for Northern Zone heating climates?

JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement supplies 468 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How much winter heat loss does Siteline Clad Wood (W-5500) Casement conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Siteline Clad Wood (W-5500) Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline Clad Wood (W-5500) Casement options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### How many Siteline Clad Wood (W-5500) Casement glazing packages pass Southern solar-heat rules?

Exactly 9,249 Siteline Clad Wood (W-5500) Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.00 rather than higher 0.44 glass.

### How many JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 458 of 9,709 Siteline Clad Wood (W-5500) Casement glazing builds earn Most Efficient recognition (4.7%), while other variants sit on the standard Version 7.0 tier.

### What federal compliance checks govern 2026 Siteline Clad Wood (W-5500) Casement window swaps?

Any Siteline Clad Wood (W-5500) Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify Siteline Clad Wood (W-5500) Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line JEL-N-877 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline Clad Wood (W-5500) Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)