title: "JELD-WEN Siteline EX Clad Wood Horizontal Slider Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-ex-clad-wood-horizontal-slider-413348/
description: "JELD-WEN Siteline EX Clad Wood Horizontal Slider (JEL-N-338, Double Slider, Wood): U-Factor 0.26-0.32, SHGC 0.12-0.23, 89 options across 2 ENERGY STAR zones."
---

Window · Wood Frame NFRC JEL · Product Line JEL-N-338

# JELD-WEN, inc. — Siteline EX Clad Wood Horizontal Slider · Double Slider

With a minimum U-Factor of 0.26—+0.06 compared against the 0.20 Window median—JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider spans 89 tested options across South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code JEL, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.23.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.12-0.23

- **Certified Options** : 89

- **Category Standing** : #1,256 of 1,352

## How does JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider compare thermally against Window peers?

JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider standing at #1,256 of 1,352 certified Window product series, tied with 35 others at 0.26, more insulating than 4.5% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.05 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-11-12 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 89 certified glazing combinations for Siteline EX Clad Wood Horizontal Slider (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 8 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 89 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Lincoln Wood Products, Inc.** — Clad Door Transom](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-door-transom-414178/) | Wood | 0.26 | 0.14 | 102 |
| [**Harvey Industries, Inc.** — Majesty Casement Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-majesty-casement-window-413295/) | Wood | 0.26 | 0.16 | 59 |
| [**Lincoln Wood Products, Inc.** — Wood Awning - Push-Out & Crank-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-awning-push-out-crank-out-414188/) | Wood | 0.26 | 0.15 | 37 |
| [**Lincoln Wood Products, Inc.** — Wood French Casement](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-french-casement-414194/) | Wood | 0.26 | 0.16 | 33 |
| [**Windsor Windows and Doors** — Pinnacle Clad Win-Pac](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-win-pac-414426/) | Wood | 0.26 | 0.14 | 267 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider appear below.

### Where does JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider stand thermally among ENERGY STAR Window lines?

Across 89 tested NFRC glazing configurations, JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider with Wood framing and Dual-Slide Horizontal (HSXX) style reaches a 0.26 minimum U-Factor and 0.12-0.23 SHGC band. It places #1,256 among 1,352 Window series—more insulating than 4.5%.

### Is Siteline EX Clad Wood Horizontal Slider approved for Northern Zone heating climates?

JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider holds zero Northern Zone qualifications (min U 0.26). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### How does a 3x5 ft Siteline EX Clad Wood Horizontal Slider window perform under a 40 deg F temperature drop?

At U 0.26, a standard 3x5 ft (15 sq ft) Siteline EX Clad Wood Horizontal Slider opening transfers 156.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +24.0 BTU/hr difference.

### When should a buyer skip JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline EX Clad Wood Horizontal Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in Siteline EX Clad Wood Horizontal Slider?

Exactly 89 Siteline EX Clad Wood Horizontal Slider options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.23 glass.

### Does Siteline EX Clad Wood Horizontal Slider carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside Siteline EX Clad Wood Horizontal Slider's 89 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What federal compliance checks govern 2026 Siteline EX Clad Wood Horizontal Slider window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Siteline EX Clad Wood Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How can homeowners confirm delivered JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line JEL-N-338 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline EX Clad Wood Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)