title: "JELD-WEN Siteline (W-550) Clad Wood Sliding Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-w-550-clad-wood-sliding-door-413375/
description: "JELD-WEN Siteline (W-550) Clad Wood Sliding Door (JEL-N-820, Sliding Patio Door, Wood): U-Factor 0.22-0.28, SHGC 0.16-0.40, 99 options across 4 ENERGY STAR."
---

Door · Wood Frame NFRC JEL · Product Line JEL-N-820

# JELD-WEN, inc. — Siteline (W-550) Clad Wood Sliding Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 99 variants inside JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door, combining Wood frame construction with U-Factors spanning 0.22 to 0.28 and SHGC 0.16 to 0.40. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #145 of 268 among 268 Door families and posts 0.01 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.16-0.40

- **Certified Options** : 99

- **Category Standing** : #145 of 268

## How does JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door compare thermally against Door peers?

JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door at rank #145 of 268 (tied with 16 others at 0.22, more insulating than 39.9% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.16-0.40 band.

Mapping NFRC SHGC values (0.16 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 46 combinations qualify in the Northern Zone alongside 69 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-11-25. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 99 certified glazing combinations for Siteline (W-550) Clad Wood Sliding Door (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 46 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 46 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 69 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 69 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Pella Corporation** — Lifestyle Series with HGP - Inswing Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-lifestyle-series-with-hgp-inswing-door-413912/) | Wood | 0.22 | 0.08 | 159 |
| [**Andersen Corporation** — A-Series Contemporary Gliding Patio Door (FWGCD)](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-contemporary-gliding-patio-door-fwgcd/) | Wood | 0.22 | 0.11 | 977 |
| [**Sierra Pacific Windows** — Aluminum Clad Inswing/Sidelite](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-aluminum-clad-inswing-sidelite-414060/) | Wood | 0.22 | 0.08 | 1,073 |
| [**Sierra Pacific Windows** — Wood Outswing/Sidelite](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-wood-outswing-sidelite-414059/) | Wood | 0.22 | 0.08 | 1,305 |
| [**Sierra Pacific Windows** — Wood Inswing Door](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-wood-inswing-door-414058/) | Wood | 0.22 | 0.08 | 1,378 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door appear below.

### How well does Siteline (W-550) Clad Wood Sliding Door by JELD-WEN, inc. insulate relative to Door benchmarks?

EPA ENERGY STAR v7.0 records 99 configurations for JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

### Which glazing options in JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door meet Northern climate limits?

Cold-climate buyers get 46 compliant Northern packages inside Siteline (W-550) Clad Wood Sliding Door, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

### What conductive BTU/hr difference separates Siteline (W-550) Clad Wood Sliding Door from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Siteline (W-550) Clad Wood Sliding Door?

Do not specify Siteline (W-550) Clad Wood Sliding Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline (W-550) Clad Wood Sliding Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Siteline (W-550) Clad Wood Sliding Door meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 69 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door, while total line SHGC reaches 0.40 in colder packages.

### Which package tier in Siteline (W-550) Clad Wood Sliding Door holds Most Efficient recognition?

Siteline (W-550) Clad Wood Sliding Door holds zero Most Efficient entries across its 99 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### What 2026 federal tax credit and Lead RRP rules apply to Siteline (W-550) Clad Wood Sliding Door?

Any Siteline (W-550) Clad Wood Sliding Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code JEL and product line JEL-N-820, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline (W-550) Clad Wood Sliding Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)