Window · Wood Frame NFRC JEL · Product Line JEL-N-885

# JELD-WEN, inc. — Siteline Wood (W-5500) Double Hung · Double Hung

Positioning #1,174/1,352 in certified Window, JELD-WEN, inc. Siteline Wood (W-5500) Double Hung pairs Wood frame with Metal-Clad Wood / Wood sash with 2,985 glazing options rated between 0.11 and 0.46 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.25 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.11-0.46

- **Certified Options** : 2,985

- **Category Standing** : #1,174 of 1,352

## How does JELD-WEN, inc. Siteline Wood (W-5500) Double Hung compare thermally against Window peers?

JELD-WEN, inc. Siteline Wood (W-5500) Double Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Siteline Wood (W-5500) Double Hung at rank #1,174 of 1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.46 band.

Mapping NFRC SHGC values (0.11 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 42 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2026-01-09 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,985 certified glazing combinations for Siteline Wood (W-5500) Double Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 42 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 50 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 421 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 2,943 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — E-Series Gliding Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-gliding-window-413002/) | Wood | 0.25 | 0.06 | 2,960 |
| [**Andersen Corporation** — Complementary Clad Casement Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-clad-casement-window-412962/) | Wood | 0.25 | 0.12 | 2,207 |
| [**Andersen Corporation** — Complementary Clad French Casement Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-clad-french-casement-window-41298/) | Wood | 0.25 | 0.12 | 2,165 |
| [**Marvin** — Ultimate Wood Outswing French Door Transom](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-outswing-french-door-transom-413616/) | Wood | 0.25 | 0.10 | 1,476 |
| [**Marvin** — Ultimate Wood Inswing French Door Transom](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-inswing-french-door-transom-413614/) | Wood | 0.25 | 0.10 | 1,355 |

## What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single SliderMin U 0.14

### [7500 Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

U-Factor 0.14–0.32 · 42,001 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-series-horizontal-slider-413396/)

Single HungMin U 0.14

### [7500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

U-Factor 0.14–0.32 · 42,169 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-7500-single-hung-413397/)

Picture WindowMin U 0.14

### [8500 Hybrid Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

U-Factor 0.14–0.32 · 53,347 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-hybrid-fixed-413393/)

Casement WindowsMin U 0.14

### [8500 PVC Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

U-Factor 0.14–0.32 · 29,919 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-casement-413392/)

Picture WindowMin U 0.14

### [8500 PVC Fixed](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

U-Factor 0.14–0.32 · 25,987 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-8500-pvc-fixed-413391/)

Picture WindowMin U 0.14

### [Premium Vinyl (V-4500) Casement Fixed Direct Set](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

U-Factor 0.14–0.32 · 2,573 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-casement-fixed-direct-set-413378/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline Wood (W-5500) Double Hung appear below.

### How efficient is JELD-WEN, inc. Siteline Wood (W-5500) Double Hung compared with peer Window models?

JELD-WEN, inc. Siteline Wood (W-5500) Double Hung spans 2,985 certified configurations with U-Factors between 0.25 and 0.32 and SHGC values from 0.11 to 0.46. Ranked #1,174 of 1,352 Window families, it carries 0 Most Efficient options.

### Is Siteline Wood (W-5500) Double Hung approved for Northern Zone heating climates?

With a 0.25 minimum U-Factor, JELD-WEN, inc. Siteline Wood (W-5500) Double Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 42 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### How does a 3x5 ft Siteline Wood (W-5500) Double Hung window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Siteline Wood (W-5500) Double Hung's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### When should a buyer skip JELD-WEN, inc. Siteline Wood (W-5500) Double Hung and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline Wood (W-5500) Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### Does Siteline Wood (W-5500) Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 2,943 Southern-certified options inside JELD-WEN, inc. Siteline Wood (W-5500) Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 2,985 Siteline Wood (W-5500) Double Hung configurations ENERGY STAR Most Efficient?

All 2,985 Siteline Wood (W-5500) Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### What federal compliance checks govern 2026 Siteline Wood (W-5500) Double Hung window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify Siteline Wood (W-5500) Double Hung after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.11-0.46) against permit drawings for line JEL-N-885. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline Wood (W-5500) Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)