title: "Kasson and Keller 220/2200 Picture Window Specs (U 0.19)"
url: https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-220-2200-picture-window-413412/
description: "Kasson and Keller 220/2200 Picture Window (KKI-K-50, Picture Window, Vinyl): U-Factor 0.19-0.26, SHGC 0.24-0.58, 143 options across 2 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC KKI · Product Line KKI-K-50 ENERGY STAR Most Efficient Eligible

# Kasson and Keller — 220/2200 Picture Window · Picture Window

With a minimum U-Factor of 0.19—-0.01 compared against the 0.20 Window median—Kasson and Keller 220/2200 Picture Window spans 143 tested options across Northern, North-Central up to 0.26 U-Factor. Carrying NFRC CPD code KKI, the Vinyl assembly includes 16 ENERGY STAR Most Efficient packages (11.2% of line) and offers SHGC packages between 0.24 and 0.58.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.24-0.58

- **Certified Options** : 143

- **Category Standing** : #564 of 1,352

## How does Kasson and Keller 220/2200 Picture Window compare thermally against Window peers?

Kasson and Keller 220/2200 Picture Window achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 220/2200 Picture Window is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.26.

Evaluating climate compliance across Northern, North-Central separates cold-weather U <= 0.22 options from cooling-dominated glazing. 16 configurations meet ENERGY STAR Most Efficient criteria while 122 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors KKI to 2024-09-27 certification (FENSTAR issued 2019-01-30). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 114.0 BTU/hr conductive loss (-13.6% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 143 certified glazing combinations for 220/2200 Picture Window (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 122 packages (16 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 57 packages (16 Most Eff.) |
| **South-Central** | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| **Southern** | Not Listed | <= 0.32 | <= 0.23 | 0 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Vinyl Design Corporation** — Double Hung](https://ela-ecolandscapingassn.org/windows/models/vinyl-design-corporation-double-hung-414233/) | Vinyl | 0.19 | 0.17 | 151 |
| [**Vinylbilt Windows and Doors 2021 Inc** — Platinum Double Hung](https://ela-ecolandscapingassn.org/windows/models/vinylbilt-windows-and-doors-2021-inc-platinum-double-hung-414222/) | Vinyl | 0.19 | 0.16 | 133 |
| [**Vinylbilt Windows and Doors 2021 Inc** — Platinum Lift Out Double Slider](https://ela-ecolandscapingassn.org/windows/models/vinylbilt-windows-and-doors-2021-inc-platinum-lift-out-double-slider/) | Vinyl | 0.19 | 0.15 | 133 |
| [**Vinylbilt Windows and Doors 2021 Inc** — Platinum Tilt Double Slider](https://ela-ecolandscapingassn.org/windows/models/vinylbilt-windows-and-doors-2021-inc-platinum-tilt-double-slider-414/) | Vinyl | 0.19 | 0.16 | 133 |
| [**Northeast Building Products Corporation** — Camelot/Crusader Elite Casement Picture Window (Sash Insert)](https://ela-ecolandscapingassn.org/windows/models/northeast-building-products-corporation-camelot-crusader-elite-casem/) | Vinyl | 0.19 | 0.17 | 156 |

## What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [700 / 7000 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-picture-window-413410/)

U-Factor 0.14–0.26 · 168 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-picture-window-413410/)

Single HungMin U 0.16

### [9100/910 Series RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9100-910-series-rr-nc-single-hung-413418/)

U-Factor 0.16–0.26 · 97 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9100-910-series-rr-nc-single-hung-413418/)

Double HungMin U 0.16

### [9200/920 Series RR/NC Double Hung](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9200-920-series-rr-nc-double-hung-413417/)

U-Factor 0.16–0.27 · 99 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9200-920-series-rr-nc-double-hung-413417/)

Awning (Projected)Min U 0.17

### [700 / 7000 Series Awning](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-awning-413409/)

U-Factor 0.17–0.32 · 290 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-awning-413409/)

Casement WindowsMin U 0.17

### [700 / 7000 Series Casement](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-casement-413408/)

U-Factor 0.17–0.32 · 296 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-casement-413408/)

Picture WindowMin U 0.19

### [300B Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-300b-picture-window-413420/)

U-Factor 0.19–0.26 · 143 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-300b-picture-window-413420/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 220/2200 Picture Window appear below.

### How well does 220/2200 Picture Window by Kasson and Keller insulate relative to Window benchmarks?

Across 143 tested NFRC glazing configurations, Kasson and Keller 220/2200 Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.19 minimum U-Factor and 0.24-0.58 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

### Is 220/2200 Picture Window approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 122 220/2200 Picture Window packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.

### How much winter heat loss does 220/2200 Picture Window conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 220/2200 Picture Window at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying 220/2200 Picture Window?

Do not specify 220/2200 Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 220/2200 Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Can you install Kasson and Keller 220/2200 Picture Window in Southern or South-Central zones?

No. With 0 Southern qualifications and SHGC starting at 0.24, 220/2200 Picture Window exceeds or misses Southern <= 0.23 requirements. Choose a spectrally selective low-SHGC series for hot climates.

### Does 220/2200 Picture Window carry EPA Most Efficient certification across its lineup?

Within 220/2200 Picture Window, 11.2% (16 of 143) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### What 2026 federal tax credit and Lead RRP rules apply to 220/2200 Picture Window?

Any 220/2200 Picture Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### What permanent glass etch marks verify 220/2200 Picture Window after sticker removal?

Verify NFRC ID KKI and series KKI-K-50 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 220/2200 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)