Window · Vinyl Frame NFRC KKI · Product Line KKI-K-52

# Kasson and Keller — 300C Double Hung · Double Hung

Kasson and Keller 300C Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.22 across 185 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.19 to 0.49.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.19-0.49

- **Certified Options** : 185

- **Category Standing** : #831 of 1,352

## How does Kasson and Keller 300C Double Hung compare thermally against Window peers?

Kasson and Keller 300C Double Hung achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Kasson and Keller 300C Double Hung standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Climate coverage for Kasson and Keller 300C Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 68 combinations qualify in the Northern Zone alongside 64 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2019-01-30 and v7.0 data certification on 2024-11-05. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 185 certified glazing combinations for 300C Double Hung (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 68 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 99 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 64 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 64 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Magnolia Window and Door** — 400/4000 Fixed](https://ela-ecolandscapingassn.org/windows/models/magnolia-window-and-door-400-4000-fixed-413545/) | Vinyl | 0.22 | 0.17 | 182 |
| [**Northeast Windows USA, Inc.** — 900 Double Hung](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-900-double-hung-413804/) | Vinyl | 0.22 | 0.09 | 168 |
| [**WeatherBarr Windows and Doors** — 4100/5100 Single Vent Casement](https://ela-ecolandscapingassn.org/windows/models/weatherbarr-windows-and-doors-4100-5100-single-vent-casement-413282/) | Vinyl | 0.22 | 0.14 | 234 |
| [**WeatherBarr Windows and Doors** — 4000 / 5000 Awning](https://ela-ecolandscapingassn.org/windows/models/weatherbarr-windows-and-doors-4000-5000-awning-413283/) | Vinyl | 0.22 | 0.14 | 237 |
| [**NT Window, Inc.** — E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-e150-executive-n150-construction-pro-x150-energy-maste/) | Vinyl | 0.22 | 0.13 | 132 |

## What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [700 / 7000 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-picture-window-413410/)

U-Factor 0.14–0.26 · 168 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-picture-window-413410/)

Single HungMin U 0.16

### [9100/910 Series RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9100-910-series-rr-nc-single-hung-413418/)

U-Factor 0.16–0.26 · 97 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9100-910-series-rr-nc-single-hung-413418/)

Double HungMin U 0.16

### [9200/920 Series RR/NC Double Hung](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9200-920-series-rr-nc-double-hung-413417/)

U-Factor 0.16–0.27 · 99 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9200-920-series-rr-nc-double-hung-413417/)

Awning (Projected)Min U 0.17

### [700 / 7000 Series Awning](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-awning-413409/)

U-Factor 0.17–0.32 · 290 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-awning-413409/)

Casement WindowsMin U 0.17

### [700 / 7000 Series Casement](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-casement-413408/)

U-Factor 0.17–0.32 · 296 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-casement-413408/)

Picture WindowMin U 0.19

### [220/2200 Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-220-2200-picture-window-413412/)

U-Factor 0.19–0.26 · 143 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-220-2200-picture-window-413412/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 300C Double Hung appear below.

### What U-Factor and SHGC range does Kasson and Keller 300C Double Hung achieve?

Across 185 tested NFRC glazing configurations, Kasson and Keller 300C Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.22 minimum U-Factor and 0.19-0.49 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

### Is 300C Double Hung approved for Northern Zone heating climates?

Cold-climate buyers get 68 compliant Northern packages inside 300C Double Hung, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.27 options.

### How do you calculate winter heat conduction for Kasson and Keller 300C Double Hung?

At U 0.22, a standard 3x5 ft (15 sq ft) 300C Double Hung opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

### What are the practical limitations of specifying 300C Double Hung?

Do not specify 300C Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 300C Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in 300C Double Hung?

Yes. 64 Southern-certified options inside Kasson and Keller 300C Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Does 300C Double Hung carry EPA Most Efficient certification across its lineup?

All 185 300C Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Do 2026 300C Double Hung installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 300C Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered Kasson and Keller 300C Double Hung units match permits?

Verify NFRC ID KKI and series KKI-K-52 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 300C Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)