title: "Kasson and Keller 700 / 7000 Series Awning Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-awning-413409/
description: "Kasson and Keller 700 / 7000 Series Awning (KKI-K-5, Awning (Projected), Vinyl): U-Factor 0.17-0.32, SHGC 0.16-0.42, 290 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC KKI · Product Line KKI-K-5 ENERGY STAR Most Efficient Eligible

# Kasson and Keller — 700 / 7000 Series Awning · Awning (Projected)

Positioning #362/1,352 in certified Window, Kasson and Keller 700 / 7000 Series Awning pairs Vinyl frame construction with 290 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 14 certified Kasson and Keller product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 108 ENERGY STAR Most Efficient packages (37.2% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.16-0.42

- **Certified Options** : 290

- **Category Standing** : #362 of 1,352

## How does Kasson and Keller 700 / 7000 Series Awning compare thermally against Window peers?

Kasson and Keller 700 / 7000 Series Awning achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 700 / 7000 Series Awning reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID KKI across multi-pane fills shifts U-Factor from 0.32 down toward 0.17.

Mapping NFRC SHGC values (0.16 to 0.42) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 108 configurations meet ENERGY STAR Most Efficient criteria while 134 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-30 licensing and 2024-04-19 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 290 certified glazing combinations for 700 / 7000 Series Awning (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 134 packages (29 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 228 packages (61 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 194 packages (58 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 220 packages (105 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Advanced Window Corp.** — 6300 Sliding Patio Door Fixed Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-sliding-patio-door-fixed-window-412860/) | Vinyl | 0.17 | 0.18 | 278 |
| [**Advanced Window Corp.** — 6300 Awning](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-awning-412855/) | Vinyl | 0.17 | 0.14 | 304 |
| [**Pella Corporation** — 250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-cws-comfort-shield-burri-413906/) | Vinyl | 0.17 | 0.15 | 254 |
| [**Pella Corporation** — 250 Series / Power Symphony / DWS Comfort Shield / Burris TectView Awning](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-dws-comfort-shield-burri/) | Vinyl | 0.17 | 0.15 | 254 |
| [**Advanced Window Corp.** — EU 76 Septem Hopper](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-hopper-412867/) | Vinyl | 0.17 | 0.10 | 339 |

## What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [700 / 7000 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-picture-window-413410/)

U-Factor 0.14–0.26 · 168 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-picture-window-413410/)

Single HungMin U 0.16

### [9100/910 Series RR/NC Single Hung](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9100-910-series-rr-nc-single-hung-413418/)

U-Factor 0.16–0.26 · 97 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9100-910-series-rr-nc-single-hung-413418/)

Double HungMin U 0.16

### [9200/920 Series RR/NC Double Hung](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9200-920-series-rr-nc-double-hung-413417/)

U-Factor 0.16–0.27 · 99 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-9200-920-series-rr-nc-double-hung-413417/)

Casement WindowsMin U 0.17

### [700 / 7000 Series Casement](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-casement-413408/)

U-Factor 0.17–0.32 · 296 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-700-7000-series-casement-413408/)

Picture WindowMin U 0.19

### [220/2200 Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-220-2200-picture-window-413412/)

U-Factor 0.19–0.26 · 143 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-220-2200-picture-window-413412/)

Picture WindowMin U 0.19

### [300B Picture Window](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-300b-picture-window-413420/)

U-Factor 0.19–0.26 · 143 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kasson-and-keller-300b-picture-window-413420/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 700 / 7000 Series Awning appear below.

### How efficient is Kasson and Keller 700 / 7000 Series Awning compared with peer Window models?

Built with Vinyl framing in Projected Awning (PRAW) style, Kasson and Keller 700 / 7000 Series Awning offers 290 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 108 Most Efficient picks.

### How does Kasson and Keller 700 / 7000 Series Awning satisfy Version 7.0 Northern criteria?

Yes. 134 packages in Kasson and Keller 700 / 7000 Series Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### How do you calculate winter heat conduction for Kasson and Keller 700 / 7000 Series Awning?

Using NFRC KKI U-Factor 0.17, a 15 sq ft Projected Awning (PRAW) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

### What homeowner profiles are a poor match for Kasson and Keller 700 / 7000 Series Awning?

Skip 700 / 7000 Series Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 700 / 7000 Series Awning options exceeding U 0.22.

### Does 700 / 7000 Series Awning meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 220 Southern-certified options inside Kasson and Keller 700 / 7000 Series Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 290 700 / 7000 Series Awning configurations ENERGY STAR Most Efficient?

Only 108 options out of 290 (37.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kasson and Keller 700 / 7000 Series Awning, usually requiring triple-pane or upgraded Low-E coatings.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 700 / 7000 Series Awning?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 700 / 7000 Series Awning retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How can homeowners confirm delivered Kasson and Keller 700 / 7000 Series Awning units match permits?

Match the NFRC thermal sticker for code KKI and line KKI-K-5 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 700 / 7000 Series Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)