---
title: "KDL Enterprises (Western Skylights) Series AV43 Fixed"
url: https://ela-ecolandscapingassn.org/windows/models/kdl-enterprises-western-skylights-series-av43-fixed-skylight-413407/
description: "KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight (KDL-A-1, Skylight, Aluminum): U-Factor 0.39-0.45, SHGC 0.28-0.48, 36 options across 1 ENERGY."
---

Skylight · Aluminum Frame NFRC KDL · Product Line KDL-A-1 ENERGY STAR Most Efficient Eligible

# KDL Enterprises (Western Skylights) — Series AV43 Fixed Skylight · Skylight

Positioning #12/16 in certified Skylight, KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight pairs Aluminum frame construction with 36 glazing options rated between 0.28 and 0.48 SHGC across Northern. Across 1 certified KDL Enterprises (Western Skylights) product families, its thermal resistance spans 0.39 to 0.45 U-Factor and the line includes 26 ENERGY STAR Most Efficient packages (72.2% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.39

- **SHGC Range** : 0.28-0.48

- **Certified Options** : 36

- **Category Standing** : #12 of 16

## How does KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight compare thermally against Skylight peers?

KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight achieves a 0.39 thermal floor across Skylight lines, placing #12 of 16 against the 0.35 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 1 certified KDL Enterprises (Western Skylights) series, this Skylight offers a 0.06 U-Factor adjustment span between 0.45 entry options and 0.39 top-performing glazing. Category standing is #12/16 (tied with 1 other at 0.39, more insulating than 18.8% of Skylight lines).

Mapping NFRC SHGC values (0.28 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern. Although its 0.39 floor sits above the 0.22 prescriptive Northern ceiling, 36 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 234.0 BTU/hr (+77.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-02-26 and cert timestamp 2024-04-15.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 36 certified glazing combinations for Series AV43 Fixed Skylight (NFRC KDL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 36 packages (26 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| **Southern** | Not Listed | <= 0.32 | <= 0.23 | 0 packages (0 Most Eff.) |

## Which competing Skylight series sit closest on U-Factor?

Inspect nearby Skylight competitors clustered closest to 0.39 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**VELUX** — TLR VELUX Sun Tunnel w/Glass Top](https://ela-ecolandscapingassn.org/windows/models/velux-tlr-velux-sun-tunnel-w-glass-top-414245/) | Aluminum | 0.39 | 0.36 | 1 |
| [**VELUX** — TCC / TCR / TGC / TGR / THR / TMR](https://ela-ecolandscapingassn.org/windows/models/velux-tcc-tcr-tgc-tgr-thr-tmr-414246/) | Aluminum | 0.37 | 0.27 | 4 |
| [**VELUX** — FS](https://ela-ecolandscapingassn.org/windows/models/velux-fs-414241/) | Wood | 0.37 | 0.17 | 21 |
| [**VELUX** — TSR 010 Rigid Tube VELUX Sun Tunnel](https://ela-ecolandscapingassn.org/windows/models/velux-tsr-010-rigid-tube-velux-sun-tunnel-414238/) | Aluminum | 0.42 | 0.40 | 1 |
| [**VELUX** — VS/VSE/VSS](https://ela-ecolandscapingassn.org/windows/models/velux-vs-vse-vss-414240/) | Wood | 0.36 | 0.14 | 17 |

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight appear below.

### Where does KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight stand thermally among ENERGY STAR Skylight lines?

EPA ENERGY STAR v7.0 records 36 configurations for KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight covering Northern, dropping down to U 0.39 versus a 0.35 Skylight median. Only 26 options earn Most Efficient status.

### Is Series AV43 Fixed Skylight approved for Northern Zone heating climates?

Because Series AV43 Fixed Skylight starts at 0.39 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 36 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

### How do you calculate winter heat conduction for KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight?

At U 0.39, a standard 3x5 ft (15 sq ft) Series AV43 Fixed Skylight opening transfers 234.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +102.0 BTU/hr difference.

### Which situations make Series AV43 Fixed Skylight the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Series AV43 Fixed Skylight options exceeding U 0.22. Additionally, do not order Fixed Skylight (SKFX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Does Series AV43 Fixed Skylight meet Southern hot-climate SHGC caps (<= 0.23)?

Southern qualification is unavailable for Series AV43 Fixed Skylight (0 qualified variants). Because its SHGC spans 0.28 to 0.48, select an alternative line explicitly rated for Southern heat rejection.

### Does Series AV43 Fixed Skylight carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 26 of 36 Series AV43 Fixed Skylight glazing builds earn Most Efficient recognition (72.2%), while other variants sit on the standard Version 7.0 tier.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Series AV43 Fixed Skylight?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 KDL Enterprises (Western Skylights) upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Series AV43 Fixed Skylight glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.39-0.45, SHGC 0.28-0.48) against permit drawings for line KDL-A-1. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for KDL Enterprises (Western Skylights) Series AV43 Fixed Skylight come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
