---
title: "Kohltech International Fiberglass Entry Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-fiberglass-entry-door-413485/
description: "Kohltech International Fiberglass Entry Door (KOI-A-60, Swinging Entry Door (Single), Wood): U-Factor 0.15-0.28, SHGC 0.01-0.33, 331883 options across 4."
---

Door · Wood Frame NFRC KOI · Product Line KOI-A-60

# Kohltech International, Ltd. — Fiberglass Entry Door · Swinging Entry Door (Single)

Across 21 Kohltech International, Ltd. certified families, Fiberglass Entry Door supplies 331,883 Swinging Entry Door, Single configurations starting at 0.15 U-Factor and 0.01 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.33 SHGC. Its thermal floor ranks #18 of 268 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.01-0.33

- **Certified Options** : 331,883

- **Category Standing** : #18 of 268

## How does Kohltech International, Ltd. Fiberglass Entry Door compare thermally against Door peers?

Kohltech International, Ltd. Fiberglass Entry Door achieves a 0.15 thermal floor across Door lines, placing #18 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Fiberglass Entry Door spans 331,883 NFRC test records (KOI), ranking #18 of 268 Door families (tied with 10 others at 0.15, more insulating than 89.6% of Door lines, top 10.4%). Its 0.15 thermal floor compares at -0.06 against the Wood median (0.21).

Mapping NFRC SHGC values (0.01 to 0.33) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 278,096 combinations qualify in the Northern Zone alongside 327,644 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-02-10 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 331,883 certified glazing combinations for Fiberglass Entry Door (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 278,096 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 278,096 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 327,644 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 327,644 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Masonite International Corporation** — Masonite Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/masonite-international-corporation-masonite-fiberglass-skin-door-414/) | Wood | 0.15 | 0.01 | 244,260 |
| [**Masonite International Corporation** — Masonite Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/masonite-international-corporation-masonite-fiberglass-skin-door-414-414133/) | Wood | 0.15 | 0.01 | 244,193 |
| [**Pella Corporation** — Pella Entry Doors - Fiberglass Skin Door](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-entry-doors-fiberglass-skin-door-413915/) | Wood | 0.15 | 0.01 | 242,982 |
| [**Specialty Wholesale Supply** — Fiberglass Entry/Patio Door](https://ela-ecolandscapingassn.org/windows/models/specialty-wholesale-supply-fiberglass-entry-patio-door-413550/) | Wood | 0.15 | 0.01 | 242,982 |
| [**Therma-Tru Corporation** — Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-fiberglass-entry-door-414156/) | Wood | 0.15 | 0.01 | 1,382 |

## What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Steel Door](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-steel-door-413482/)

U-Factor 0.13–0.28 · 77,762 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-steel-door-413482/)

Picture WindowMin U 0.14

### [2020 Supreme Narrow Picture](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-narrow-picture-413497/)

U-Factor 0.14–0.25 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-narrow-picture-413497/)

Awning (Projected)Min U 0.15

### [2020 Supreme Awning](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-awning-413499/)

U-Factor 0.15–0.26 · 29 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-awning-413499/)

Casement WindowsMin U 0.15

### [2020 Supreme Casement](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-casement-413496/)

U-Factor 0.15–0.26 · 31 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-casement-413496/)

Picture WindowMin U 0.15

### [2020 Supreme Wide Picture](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-wide-picture-413498/)

U-Factor 0.15–0.25 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-wide-picture-413498/)

SideliteMin U 0.15

### [Fiberglass Sidelite](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-fiberglass-sidelite-413486/)

U-Factor 0.15–0.28 · 394,477 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-fiberglass-sidelite-413486/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. Fiberglass Entry Door appear below.

### Where does Kohltech International, Ltd. Fiberglass Entry Door stand thermally among ENERGY STAR Door lines?

Kohltech International, Ltd. Fiberglass Entry Door spans 331,883 certified configurations with U-Factors between 0.15 and 0.28 and SHGC values from 0.01 to 0.33. Ranked #18 of 268 Door families, it carries 0 Most Efficient options.

### Does Kohltech International, Ltd. Fiberglass Entry Door qualify for the ENERGY STAR Northern Zone?

Yes. 278,096 packages in Kohltech International, Ltd. Fiberglass Entry Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

### What BTU/hr heat transfer results from Fiberglass Entry Door's 0.15 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Fiberglass Entry Door at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying Fiberglass Entry Door?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Fiberglass Entry Door options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### What Southern ENERGY STAR v7.0 options exist in Fiberglass Entry Door?

Exactly 327,644 Fiberglass Entry Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.01 rather than higher 0.33 glass.

### Which package tier in Fiberglass Entry Door holds Most Efficient recognition?

Zero glazing builds inside Fiberglass Entry Door's 331,883 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What 2026 federal tax credit and Lead RRP rules apply to Fiberglass Entry Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kohltech International, Ltd. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Fiberglass Entry Door glass specs on job sites?

Verify NFRC ID KOI and series KOI-A-60 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. Fiberglass Entry Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
