title: "Kohltech International S-100 Sidelite Specs (U 0.15)"
url: https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-s-100-sidelite-413481/
description: "Kohltech International S-100 Sidelite (KOI-A-33, Sidelite, Vinyl / Wood): U-Factor 0.15-0.24, SHGC 0.23-0.32, 20 options across 4 ENERGY STAR zones."
---

Window · Vinyl / Wood Frame NFRC KOI · Product Line KOI-A-33

# Kohltech International, Ltd. — S-100 Sidelite · Sidelite

Across 21 Kohltech International, Ltd. certified families, S-100 Sidelite supplies 20 Sidelite configurations starting at 0.15 U-Factor and 0.23 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.24 U-Factor and 0.32 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.23-0.32

- **Certified Options** : 20

- **Category Standing** : #136 of 1,352

## How does Kohltech International, Ltd. S-100 Sidelite compare thermally against Window peers?

Kohltech International, Ltd. S-100 Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across S-100 Sidelite spans 20 NFRC test records (KOI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at +0.01 against the Vinyl / Wood median (0.14).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 20 combinations qualify in the Northern Zone alongside 2 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Lifecycle documentation anchors KOI to 2025-02-10 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 20 certified glazing combinations for S-100 Sidelite (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 20 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 20 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 2 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 2 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**DRUTEX S.A.** — IGLO EDGE Fixed Window](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-edge-fixed-window-413180/) | Vinyl | 0.15 | 0.21 | 26 |
| [**Foshan Xiaoluban Doors and Windows Co., Ltd.** — XLB-80 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/foshan-xiaoluban-doors-and-windows-co-ltd-xlb-80-fixed-window-413252/) | Aluminum | 0.15 | 0.17 | 7 |
| [**OKNA Windows & Doors Mfg** — 410 Picture Window](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-410-picture-window-413865/) | Vinyl | 0.15 | 0.16 | 56 |
| [**Vector Windows** — Envision Casement Picture](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-casement-picture-414024/) | Vinyl | 0.15 | 0.18 | 57 |
| [**OKNA Windows & Doors Mfg** — 7500 Double Hung](https://ela-ecolandscapingassn.org/windows/models/okna-windows-doors-mfg-7500-double-hung-413874/) | Vinyl | 0.15 | 0.15 | 59 |

## What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Swinging Entry Door (Single)Min U 0.13

### [Steel Door](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-steel-door-413482/)

U-Factor 0.13–0.28 · 77,762 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-steel-door-413482/)

Picture WindowMin U 0.14

### [2020 Supreme Narrow Picture](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-narrow-picture-413497/)

U-Factor 0.14–0.25 · 22 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-narrow-picture-413497/)

Awning (Projected)Min U 0.15

### [2020 Supreme Awning](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-awning-413499/)

U-Factor 0.15–0.26 · 29 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-awning-413499/)

Casement WindowsMin U 0.15

### [2020 Supreme Casement](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-casement-413496/)

U-Factor 0.15–0.26 · 31 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-casement-413496/)

Picture WindowMin U 0.15

### [2020 Supreme Wide Picture](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-wide-picture-413498/)

U-Factor 0.15–0.25 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-2020-supreme-wide-picture-413498/)

Swinging Entry Door (Single)Min U 0.15

### [Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-fiberglass-entry-door-413485/)

U-Factor 0.15–0.28 · 331,883 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-fiberglass-entry-door-413485/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. S-100 Sidelite appear below.

### How well does S-100 Sidelite by Kohltech International, Ltd. insulate relative to Window benchmarks?

Across 20 tested NFRC glazing configurations, Kohltech International, Ltd. S-100 Sidelite with Vinyl / Wood framing and Fixed Sidelite (FXSL) style reaches a 0.15 minimum U-Factor and 0.23-0.32 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

### Which glazing options in Kohltech International, Ltd. S-100 Sidelite meet Northern climate limits?

Yes, 20 packages satisfy Northern ENERGY STAR Version 7.0 rules in S-100 Sidelite. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How much winter heat loss does S-100 Sidelite conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), S-100 Sidelite at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Which situations make S-100 Sidelite the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S-100 Sidelite options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is S-100 Sidelite suitable for sunbelt cooling-dominated homes?

Yes, S-100 Sidelite holds 2 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.23 SHGC in cooling climates.

### What glazing share inside S-100 Sidelite qualifies as Most Efficient?

No. Zero of the 20 configurations in Kohltech International, Ltd. S-100 Sidelite hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect S-100 Sidelite?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current S-100 Sidelite retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do building inspectors verify S-100 Sidelite glass specs on job sites?

Match the NFRC thermal sticker for code KOI and line KOI-A-33 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. S-100 Sidelite come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)