title: "Kolbe and Kolbe Millwork Heritage Casement Specs (U 0.15)"
url: https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-casement-413429/
description: "Kolbe and Kolbe Millwork Heritage Casement (KKM-N-126, Casement Windows, Wood): U-Factor 0.15-0.32, SHGC 0.09-0.43, 1084 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC KKM · Product Line KKM-N-126 ENERGY STAR Most Efficient Eligible

# Kolbe and Kolbe Millwork Co., Inc — Heritage Casement · Casement Windows

Kolbe and Kolbe Millwork Co., Inc Heritage Casement is a Casement Windows assembly with a Wood frame that reaches a minimum U-Factor of 0.15 across 1,084 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.43.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.09-0.43

- **Certified Options** : 1,084

- **Category Standing** : #136 of 1,352

## How does Kolbe and Kolbe Millwork Co., Inc Heritage Casement compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Heritage Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 57 certified Kolbe and Kolbe Millwork Co., Inc series, this Casement Windows offers a 0.17 U-Factor adjustment span between 0.32 entry options and 0.15 top-performing glazing. Category standing is #136/1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 510 configurations meet ENERGY STAR Most Efficient criteria while 229 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-07-29 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,084 certified glazing combinations for Heritage Casement (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 229 packages (172 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 647 packages (508 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 739 packages (406 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 957 packages (406 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Pinnacle Clad Radius Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/) | Wood | 0.15 | 0.13 | 1,266 |
| [**Lepage Millwork** — Fixed XL Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-fixed-xl-hung-413516/) | Wood | 0.15 | 0.16 | 154 |
| [**Marvin** — Elevate Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/marvin-elevate-direct-glaze-413573/) | Wood | 0.15 | 0.13 | 2,250 |
| [**Andersen Corporation** — 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-transom-full-f/) | Wood | 0.15 | 0.13 | 2,446 |
| [**Pella Corporation** — Architect Wood Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-wood-fixed-casement-413886/) | Wood | 0.15 | 0.11 | 2,468 |

## What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.09

### [Heritage Direct Set HWC2D](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-direct-set-hwc2d-413423/)

U-Factor 0.09–0.32 · 1,006 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-direct-set-hwc2d-413423/)

Picture WindowMin U 0.10

### [Forgent Casement Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-direct-set-413447/)

U-Factor 0.10–0.32 · 2,618 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-direct-set-413447/)

Picture WindowMin U 0.10

### [Forgent DH Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-dh-direct-set-413443/)

U-Factor 0.10–0.32 · 2,055 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-dh-direct-set-413443/)

Picture WindowMin U 0.11

### [Forgent Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-picture-413460/)

U-Factor 0.11–0.32 · 2,196 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-picture-413460/)

Picture WindowMin U 0.11

### [Heritage Casement Picture Sash Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-casement-picture-sash-set-4/)

U-Factor 0.11–0.31 · 1,234 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-casement-picture-sash-set-4/)

Picture WindowMin U 0.11

### [VistaLuxe Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-vistaluxe-direct-set-413452/)

U-Factor 0.11–0.32 · 1,439 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-vistaluxe-direct-set-413452/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Heritage Casement appear below.

### How efficient is Kolbe and Kolbe Millwork Co., Inc Heritage Casement compared with peer Window models?

Testing puts Kolbe and Kolbe Millwork Co., Inc Heritage Casement at rank #136 of 1,352 Window entries with U 0.15 to 0.32 across 1,084 configurations. Solar heat gain ranges between 0.09 and 0.43 across Northern, North-Central, South-Central, Southern.

### Is Heritage Casement approved for Northern Zone heating climates?

Cold-climate buyers get 229 compliant Northern packages inside Heritage Casement, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### What conductive BTU/hr difference separates Heritage Casement from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 90.0 BTU/hr on Heritage Casement's lowest-U package (0.15), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Which situations make Heritage Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Heritage Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in Heritage Casement?

Warm-climate homeowners have 957 Southern-approved options within Heritage Casement spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### How many Kolbe and Kolbe Millwork Co., Inc Heritage Casement variants earn ENERGY STAR Most Efficient?

EPA lists 510 Most Efficient options (47.0% share) inside Kolbe and Kolbe Millwork Co., Inc Heritage Casement, out of 1,084 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Heritage Casement?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on Heritage Casement?

Inspectors match the temporary NFRC sticker (U 0.15-0.32, SHGC 0.09-0.43) against permit drawings for line KKM-N-126. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Heritage Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)