title: "Kolbe and Kolbe Millwork Ultra Casement_Sliding Door"
url: https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-casement-sliding-door-transom/
description: "Kolbe and Kolbe Millwork Ultra Casement_Sliding Door Transom Sash Set (KKM-N-280, Picture Window, Wood): U-Factor 0.14-0.32, SHGC 0.09-0.46, 1868 options."
---

Window · Wood Frame NFRC KKM · Product Line KKM-N-280 ENERGY STAR Most Efficient Eligible

# Kolbe and Kolbe Millwork Co., Inc — Ultra Casement_Sliding Door Transom Sash Set · Picture Window

Kolbe and Kolbe Millwork Co., Inc engineered the Ultra Casement_Sliding Door Transom Sash Set Picture Window line for Northern, North-Central, South-Central, Southern, certifying 1,868 glass-spacer combinations from 0.14 to 0.32 U-Factor and 0.09 to 0.46 SHGC. Relative to other Wood models tracked under NFRC KKM, its minimum U-Factor is 0.07 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.09-0.46

- **Certified Options** : 1,868

- **Category Standing** : #72 of 1,352

## How does Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set at rank #72 of 1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.46 band.

Climate coverage for Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 1,054 configurations meet ENERGY STAR Most Efficient criteria while 465 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2026-06-22. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.14 conducts 84.0 BTU/hr (-48.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,868 certified glazing combinations for Ultra Casement_Sliding Door Transom Sash Set (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 465 packages (342 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,157 packages (1,044 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,282 packages (827 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1,611 packages (827 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Sierra Pacific Windows** — Clad Aspen Fixed](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/) | Wood | 0.14 | 0.10 | 1,585 |
| [**Lepage Millwork** — Wood Direct Set (TF-100)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-direct-set-tf-100-413519/) | Wood | 0.14 | 0.19 | 90 |
| [**JELD-WEN, inc.** — Siteline Clad Wood (W-5500) Fixed Direct Set Geo](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-w-5500-fixed-direct-set-geo-413384/) | Wood | 0.14 | 0.13 | 4,582 |
| [**Weather Shield Mfg., Inc.** — 630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/) | Wood | 0.14 | 0.13 | 5,555 |
| [**Andersen Corporation** — Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/) | Wood | 0.14 | 0.14 | 7,588 |

## What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.09

### [Heritage Direct Set HWC2D](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-direct-set-hwc2d-413423/)

U-Factor 0.09–0.32 · 1,006 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-direct-set-hwc2d-413423/)

Picture WindowMin U 0.10

### [Forgent Casement Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-direct-set-413447/)

U-Factor 0.10–0.32 · 2,618 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-direct-set-413447/)

Picture WindowMin U 0.10

### [Forgent DH Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-dh-direct-set-413443/)

U-Factor 0.10–0.32 · 2,055 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-dh-direct-set-413443/)

Picture WindowMin U 0.11

### [Forgent Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-picture-413460/)

U-Factor 0.11–0.32 · 2,196 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-picture-413460/)

Picture WindowMin U 0.11

### [Heritage Casement Picture Sash Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-casement-picture-sash-set-4/)

U-Factor 0.11–0.31 · 1,234 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-casement-picture-sash-set-4/)

Picture WindowMin U 0.11

### [VistaLuxe Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-vistaluxe-direct-set-413452/)

U-Factor 0.11–0.32 · 1,439 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-vistaluxe-direct-set-413452/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set appear below.

### What U-Factor and SHGC range does Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set achieve?

Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set spans 1,868 certified configurations with U-Factors between 0.14 and 0.32 and SHGC values from 0.09 to 0.46. Ranked #72 of 1,352 Window families, it carries 1,054 Most Efficient options.

### How does Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set satisfy Version 7.0 Northern criteria?

Yes, 465 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultra Casement_Sliding Door Transom Sash Set. Pairing multi-pane insulation down to 0.14 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How much winter heat loss does Ultra Casement_Sliding Door Transom Sash Set conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 84.0 BTU/hr on Ultra Casement_Sliding Door Transom Sash Set's lowest-U package (0.14), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Which situations make Ultra Casement_Sliding Door Transom Sash Set the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Casement_Sliding Door Transom Sash Set options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set in Southern or South-Central zones?

Exactly 1,611 Ultra Casement_Sliding Door Transom Sash Set options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.46 glass.

### Which package tier in Ultra Casement_Sliding Door Transom Sash Set holds Most Efficient recognition?

EPA lists 1,054 Most Efficient options (56.4% share) inside Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set, out of 1,868 total Version 7.0 entries.

### What federal compliance checks govern 2026 Ultra Casement_Sliding Door Transom Sash Set window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### Where are NFRC and IGCC identification marks located on Ultra Casement_Sliding Door Transom Sash Set?

Verify NFRC ID KKM and series KKM-N-280 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Casement_Sliding Door Transom Sash Set come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)