---
title: "Kolbe and Kolbe Millwork Ultra Push-Out Casement Picture"
url: https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-push-out-casement-picture-4134/
description: "Kolbe and Kolbe Millwork Ultra Push-Out Casement Picture (KKM-N-287, Picture Window, Wood): U-Factor 0.14-0.32, SHGC 0.10-0.47, 2719 options across 4 ENERGY."
---

Window · Wood Frame NFRC KKM · Product Line KKM-N-287 ENERGY STAR Most Efficient Eligible

# Kolbe and Kolbe Millwork Co., Inc — Ultra Push-Out Casement Picture · Picture Window

Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.14 across 2,719 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #72 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.47.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.10-0.47

- **Certified Options** : 2,719

- **Category Standing** : #72 of 1,352

## How does Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultra Push-Out Casement Picture spans 2,719 NFRC test records (KKM), ranking #72 of 1,352 Window families (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%). Its 0.14 thermal floor compares at -0.07 against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 1,492 configurations meet ENERGY STAR Most Efficient criteria while 794 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2026-05-04 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,719 certified glazing combinations for Ultra Push-Out Casement Picture (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 794 packages (576 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,650 packages (1,400 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,767 packages (1,106 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,324 packages (1,160 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Sierra Pacific Windows** — Clad Aspen Fixed](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/) | Wood | 0.14 | 0.10 | 1,585 |
| [**JELD-WEN, inc.** — Siteline Clad Wood (W-5500) Fixed Direct Set Geo](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-w-5500-fixed-direct-set-geo-413384/) | Wood | 0.14 | 0.13 | 4,582 |
| [**Lepage Millwork** — Wood Direct Set (TF-100)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-direct-set-tf-100-413519/) | Wood | 0.14 | 0.19 | 90 |
| [**Weather Shield Mfg., Inc.** — 630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/) | Wood | 0.14 | 0.13 | 5,555 |
| [**Andersen Corporation** — Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/) | Wood | 0.14 | 0.14 | 7,588 |

## What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.09

### [Heritage Direct Set HWC2D](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-direct-set-hwc2d-413423/)

U-Factor 0.09–0.32 · 1,006 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-direct-set-hwc2d-413423/)

Picture WindowMin U 0.10

### [Forgent Casement Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-direct-set-413447/)

U-Factor 0.10–0.32 · 2,618 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-direct-set-413447/)

Picture WindowMin U 0.10

### [Forgent DH Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-dh-direct-set-413443/)

U-Factor 0.10–0.32 · 2,055 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-dh-direct-set-413443/)

Picture WindowMin U 0.11

### [Forgent Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-picture-413460/)

U-Factor 0.11–0.32 · 2,196 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-forgent-casement-picture-413460/)

Picture WindowMin U 0.11

### [Heritage Casement Picture Sash Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-casement-picture-sash-set-4/)

U-Factor 0.11–0.31 · 1,234 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-casement-picture-sash-set-4/)

Picture WindowMin U 0.11

### [VistaLuxe Direct Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-vistaluxe-direct-set-413452/)

U-Factor 0.11–0.32 · 1,439 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-vistaluxe-direct-set-413452/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture appear below.

### How efficient is Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture compared with peer Window models?

Testing puts Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture at rank #72 of 1,352 Window entries with U 0.14 to 0.32 across 2,719 configurations. Solar heat gain ranges between 0.10 and 0.47 across Northern, North-Central, South-Central, Southern.

### Is Ultra Push-Out Casement Picture approved for Northern Zone heating climates?

Cold-climate buyers get 794 compliant Northern packages inside Ultra Push-Out Casement Picture, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### How much winter heat loss does Ultra Push-Out Casement Picture conduct across a 15 sq ft opening?

At U 0.14, a standard 3x5 ft (15 sq ft) Ultra Push-Out Casement Picture opening transfers 84.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -48.0 BTU/hr difference.

### What homeowner profiles are a poor match for Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Push-Out Casement Picture options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many Ultra Push-Out Casement Picture glazing packages pass Southern solar-heat rules?

Yes. 2,324 Southern-certified options inside Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.47 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture variants earn ENERGY STAR Most Efficient?

No. Exactly 1,492 of 2,719 configurations (54.9%) earn ENERGY STAR Most Efficient status in Ultra Push-Out Casement Picture; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 Ultra Push-Out Casement Picture installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### What permanent glass etch marks verify Ultra Push-Out Casement Picture after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line KKM-N-287 and NFRC ID KKM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Push-Out Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
