---
title: "KP Building Products Limited 2100/6500 Casement, 2120/6520"
url: https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-2100-6500-casement-2120-6520-fixed-case/
description: "KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement (FAR-M-31, Casement Windows, Vinyl): U-Factor 0.23-0.24, SHGC 0.18-0.47, 8 options."
---

Window · Vinyl Frame NFRC FAR · Product Line FAR-M-31

# KP Building Products Limited — 2100/6500 Casement, 2120/6520 Fixed Casement · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 8 variants inside KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement, combining Vinyl frame construction with U-Factors spanning 0.23 to 0.24 and SHGC 0.18 to 0.47. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #936 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.18-0.47

- **Certified Options** : 8

- **Category Standing** : #936 of 1,352

## How does KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement compare thermally against Window peers?

KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 15 certified KP Building Products Limited series, this Casement Windows offers a 0.01 U-Factor adjustment span between 0.24 entry options and 0.23 top-performing glazing. Category standing is #936/1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-02-11 and FENSTAR license 2018-06-13 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8 certified glazing combinations for 2100/6500 Casement, 2120/6520 Fixed Casement (NFRC FAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 4 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 4 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 4 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Taylors Window and Screen, Inc.** — 8501 NC/Repl Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-8501-nc-repl-casement-picture-window-4/) | Vinyl | 0.23 | 0.18 | 18 |
| [**Morfe Windows LLC** — Horizontal Sliding Window](https://ela-ecolandscapingassn.org/windows/models/morfe-windows-llc-horizontal-sliding-window-413791/) | Vinyl | 0.23 | 0.18 | 20 |
| [**Vytex Corporation** — Grandview Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-grandview-horizontal-slider-414301/) | Vinyl | 0.23 | 0.19 | 21 |
| [**Vytex Corporation** — Grandview Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-grandview-double-hung-414302/) | Vinyl | 0.23 | 0.19 | 22 |
| [**California Deluxe Windows Industries, Inc.** — S-3480 Single Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/) | Vinyl | 0.23 | 0.12 | 28 |

## What other certified series does KP Building Products Limited produce?

Compare other active KP Building Products Limited certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.17

### [4020/5020/6020 Fixed Picture](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-4020-5020-6020-fixed-picture-413237/)

U-Factor 0.17–0.23 · 28 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-4020-5020-6020-fixed-picture-413237/)

Picture WindowMin U 0.17

### [5120/6120/7120 Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-5120-6120-7120-fixed-casement-413236/)

U-Factor 0.17–0.25 · 32 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-5120-6120-7120-fixed-casement-413236/)

Casement WindowsMin U 0.18

### [5100/6100/7100 Casement](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-5100-6100-7100-casement-413234/)

U-Factor 0.18–0.24 · 14 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-5100-6100-7100-casement-413234/)

Awning (Projected)Min U 0.18

### [5110/6110/7110 Awning](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-5110-6110-7110-awning-413235/)

U-Factor 0.18–0.24 · 14 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-5110-6110-7110-awning-413235/)

Awning (Projected)Min U 0.23

### [2110/6510 Awning](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-2110-6510-awning-413239/)

U-Factor 0.23–0.25 · 4 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-2110-6510-awning-413239/)

Picture WindowMin U 0.23

### [3020/3520 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-3020-3520-fixed-window-413242/)

U-Factor 0.23–0.24 · 8 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/kp-building-products-limited-3020-3520-fixed-window-413242/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement appear below.

### What thermal performance numbers separate KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement from peers?

Testing puts KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement at rank #936 of 1,352 Window entries with U 0.23 to 0.24 across 8 configurations. Solar heat gain ranges between 0.18 and 0.47 across Northern, North-Central, South-Central, Southern.

### Does KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement qualify for the ENERGY STAR Northern Zone?

Northern qualification on 2100/6500 Casement, 2120/6520 Fixed Casement relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 4 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

### What conductive BTU/hr difference separates 2100/6500 Casement, 2120/6520 Fixed Casement from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement?

Do not specify 2100/6500 Casement, 2120/6520 Fixed Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 2100/6500 Casement, 2120/6520 Fixed Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does 2100/6500 Casement, 2120/6520 Fixed Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 4 Southern-certified options inside KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.47 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside 2100/6500 Casement, 2120/6520 Fixed Casement's 8 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What 2026 federal tax credit and Lead RRP rules apply to 2100/6500 Casement, 2120/6520 Fixed Casement?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 2100/6500 Casement, 2120/6520 Fixed Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do building inspectors verify 2100/6500 Casement, 2120/6520 Fixed Casement glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.23-0.24, SHGC 0.18-0.47) against permit drawings for line FAR-M-31. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for KP Building Products Limited 2100/6500 Casement, 2120/6520 Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
