---
title: "L.A.S. Enterprises Weathergard II - Vinyl Picture Specs"
url: https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-picture-413524/
description: "L.A.S. Enterprises Weathergard II - Vinyl Picture (LSE-M-7, Picture Window, Vinyl): U-Factor 0.24-0.25, SHGC 0.14-0.56, 44 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC LSE · Product Line LSE-M-7

# L.A.S. Enterprises — Weathergard II - Vinyl Picture · Picture Window

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—L.A.S. Enterprises Weathergard II - Vinyl Picture spans 44 tested options across Northern, North-Central, South-Central, Southern up to 0.25 U-Factor. Carrying NFRC CPD code LSE, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.14 and 0.56.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.14-0.56

- **Certified Options** : 44

- **Category Standing** : #1,034 of 1,352

## How does L.A.S. Enterprises Weathergard II - Vinyl Picture compare thermally against Window peers?

L.A.S. Enterprises Weathergard II - Vinyl Picture achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 5 certified L.A.S. Enterprises series, this Picture Window offers a 0.01 U-Factor adjustment span between 0.25 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors LSE to 2025-08-28 certification (FENSTAR issued 2018-10-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 44 certified glazing combinations for Weathergard II - Vinyl Picture (NFRC LSE) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 40 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 40 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 40 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Target Windows and Doors** — SL 3000 Single Hung](https://ela-ecolandscapingassn.org/windows/models/target-windows-and-doors-sl-3000-single-hung-414142/) | Vinyl | 0.24 | 0.20 | 42 |
| [**Target Windows and Doors** — SL 3050 Single Slider](https://ela-ecolandscapingassn.org/windows/models/target-windows-and-doors-sl-3050-single-slider-414143/) | Vinyl | 0.24 | 0.20 | 42 |
| [**California Deluxe Windows Industries, Inc.** — S-3725/3735 Single Slider](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3725-3735-single-slider-4/) | Vinyl | 0.24 | 0.12 | 40 |
| [**Comfort View Products, LLC** — 1901 Picture Window](https://ela-ecolandscapingassn.org/windows/models/comfort-view-products-llc-1901-picture-window-413126/) | Vinyl | 0.24 | 0.21 | 40 |
| [**Crystal Window and Door Systems, Ltd.** — 100 Series Double Hung](https://ela-ecolandscapingassn.org/windows/models/crystal-window-and-door-systems-ltd-100-series-double-hung-413116/) | Vinyl | 0.24 | 0.16 | 48 |

## What other certified series does L.A.S. Enterprises produce?

Compare other active L.A.S. Enterprises certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Double HungMin U 0.19

### [Weathergard II - Vinyl Double Hung](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-double-hung-413523/)

U-Factor 0.19–0.29 · 210 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-double-hung-413523/)

Double SliderMin U 0.19

### [Weathergard II - Vinyl Double Slider](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-double-slider-413522/)

U-Factor 0.19–0.29 · 210 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-double-slider-413522/)

Casement WindowsMin U 0.24

### [Weathergard II - Vinyl Casement](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-casement-413521/)

U-Factor 0.24–0.25 · 44 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-casement-413521/)

Single HungMin U 0.28

### [Weathergard II - Vinyl Single Hung](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-single-hung-413525/)

U-Factor 0.28–0.28 · 60 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-single-hung-413525/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to L.A.S. Enterprises Weathergard II - Vinyl Picture appear below.

### How efficient is L.A.S. Enterprises Weathergard II - Vinyl Picture compared with peer Window models?

Built with Vinyl framing in Fixed Window (FIXD) style, L.A.S. Enterprises Weathergard II - Vinyl Picture offers 44 Version 7.0 configurations from U 0.24 up to 0.25, posting +0.04 against the Window median of 0.20 with 0 Most Efficient picks.

### Which glazing options in L.A.S. Enterprises Weathergard II - Vinyl Picture meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above Weathergard II - Vinyl Picture's 0.24 minimum. However, 4 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### How much winter heat loss does Weathergard II - Vinyl Picture conduct across a 15 sq ft opening?

At U 0.24, a standard 3x5 ft (15 sq ft) Weathergard II - Vinyl Picture opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

### What are the practical limitations of specifying Weathergard II - Vinyl Picture?

Do not specify Weathergard II - Vinyl Picture without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Weathergard II - Vinyl Picture options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Weathergard II - Vinyl Picture meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 40 Southern-approved options within Weathergard II - Vinyl Picture spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Does Weathergard II - Vinyl Picture carry EPA Most Efficient certification across its lineup?

Weathergard II - Vinyl Picture holds zero Most Efficient entries across its 44 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### What federal compliance checks govern 2026 Weathergard II - Vinyl Picture window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Weathergard II - Vinyl Picture retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do building inspectors verify Weathergard II - Vinyl Picture glass specs on job sites?

Verify NFRC ID LSE and series LSE-M-7 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for L.A.S. Enterprises Weathergard II - Vinyl Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
