title: "Lepage Millwork Wood Awning C-100 Specs (U 0.19)"
url: https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-awning-c-100-413517/
description: "Lepage Millwork Wood Awning C-100 (LEP-M-75, Awning (Projected), Wood): U-Factor 0.19-0.32, SHGC 0.15-0.45, 281 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC LEP · Product Line LEP-M-75 ENERGY STAR Most Efficient Eligible

# Lepage Millwork — Wood Awning C-100 · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 281 variants inside Lepage Millwork Wood Awning C-100, combining Wood frame construction with U-Factors spanning 0.19 to 0.32 and SHGC 0.15 to 0.45. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #564 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.15-0.45

- **Certified Options** : 281

- **Category Standing** : #564 of 1,352

## How does Lepage Millwork Wood Awning C-100 compare thermally against Window peers?

Lepage Millwork Wood Awning C-100 achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Lepage Millwork Wood Awning C-100 at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.15-0.45 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 38 configurations meet ENERGY STAR Most Efficient criteria while 48 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-07-17 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 114.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 281 certified glazing combinations for Wood Awning C-100 (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 48 packages (9 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 87 packages (15 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 157 packages (15 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 249 packages (38 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Pella Corporation** — Pella Architect Clad Awning](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-architect-clad-awning-413883/) | Wood | 0.19 | 0.11 | 547 |
| [**Lincoln Wood Products, Inc.** — Clad Casement Studio (Transom) - Crank-Out & Push-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-casement-studio-transom-crank-out-pus/) | Wood | 0.19 | 0.16 | 598 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Awning](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-awning-413458/) | Wood | 0.19 | 0.09 | 908 |
| [**Pella Corporation** — Architect Clad Casement](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-architect-clad-casement-413882/) | Wood | 0.19 | 0.11 | 1,129 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Series Swing Door Transom](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-series-swing-door-transom-4134/) | Wood | 0.19 | 0.09 | 2,084 |

## What other certified series does Lepage Millwork produce?

Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [Wood Direct Set (TF-100)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-direct-set-tf-100-413519/)

U-Factor 0.14–0.32 · 90 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-direct-set-tf-100-413519/)

Picture WindowMin U 0.15

### [Fixed XL Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-fixed-xl-hung-413516/)

U-Factor 0.15–0.32 · 154 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-fixed-xl-hung-413516/)

Picture WindowMin U 0.16

### [Wood Fixed Casement C-100](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-fixed-casement-c-100-413518/)

U-Factor 0.16–0.32 · 282 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-fixed-casement-c-100-413518/)

Sliding Patio DoorMin U 0.17

### [Lift & Slide Door](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-lift-slide-door-413514/)

U-Factor 0.17–0.28 · 165 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-lift-slide-door-413514/)

Double HungMin U 0.17

### [XL-300 & XL-200 Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-300-xl-200-hung-413515/)

U-Factor 0.17–0.32 · 108 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-300-xl-200-hung-413515/)

Sliding Patio DoorMin U 0.18

### [MultiSlide Patio Door (Wood and Clad)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-multislide-patio-door-wood-and-clad-413520/)

U-Factor 0.18–0.28 · 132 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-multislide-patio-door-wood-and-clad-413520/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork Wood Awning C-100 appear below.

### Where does Lepage Millwork Wood Awning C-100 stand thermally among ENERGY STAR Window lines?

Built with Wood framing in Projected Awning (PRAW) style, Lepage Millwork Wood Awning C-100 offers 281 Version 7.0 configurations from U 0.19 up to 0.32, posting -0.01 against the Window median of 0.20 with 38 Most Efficient picks.

### Does Lepage Millwork Wood Awning C-100 qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 48 Wood Awning C-100 packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### How much winter heat loss does Wood Awning C-100 conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip Lepage Millwork Wood Awning C-100 and compare alternatives?

Do not specify Wood Awning C-100 without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Awning C-100 options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many Wood Awning C-100 glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 249 Southern-approved options within Wood Awning C-100 spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### What glazing share inside Wood Awning C-100 qualifies as Most Efficient?

Not every package qualifies: 38 of 281 Wood Awning C-100 glazing builds earn Most Efficient recognition (13.5%), while other variants sit on the standard Version 7.0 tier.

### What 2026 federal tax credit and Lead RRP rules apply to Wood Awning C-100?

Any Wood Awning C-100 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered Lepage Millwork Wood Awning C-100 units match permits?

Inspectors match the temporary NFRC sticker (U 0.19-0.32, SHGC 0.15-0.45) against permit drawings for line LEP-M-75. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lepage Millwork Wood Awning C-100 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)