title: "Lepage Millwork Wood Direct Set (TF-100) Specs (U 0.14)"
url: https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-direct-set-tf-100-413519/
description: "Lepage Millwork Wood Direct Set (TF-100) (LEP-M-77, Picture Window, Wood): U-Factor 0.14-0.32, SHGC 0.19-0.60, 90 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC LEP · Product Line LEP-M-77 ENERGY STAR Most Efficient Eligible

# Lepage Millwork — Wood Direct Set (TF-100) · Picture Window

Across 10 Lepage Millwork certified families, Wood Direct Set (TF-100) supplies 90 Picture Window configurations starting at 0.14 U-Factor and 0.19 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.60 SHGC. Its thermal floor ranks #72 of 1,352 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.19-0.60

- **Certified Options** : 90

- **Category Standing** : #72 of 1,352

## How does Lepage Millwork Wood Direct Set (TF-100) compare thermally against Window peers?

Lepage Millwork Wood Direct Set (TF-100) achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 10 certified Lepage Millwork series, this Picture Window offers a 0.18 U-Factor adjustment span between 0.32 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Mapping NFRC SHGC values (0.19 to 0.60) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 27 configurations meet ENERGY STAR Most Efficient criteria while 46 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2026-07-17 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 90 certified glazing combinations for Wood Direct Set (TF-100) (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 46 packages (20 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 55 packages (18 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 35 packages (5 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 42 packages (10 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Sierra Pacific Windows** — Clad Aspen Fixed](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/) | Wood | 0.14 | 0.10 | 1,585 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Casement_Sliding Door Transom Sash Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-casement-sliding-door-transom/) | Wood | 0.14 | 0.09 | 1,868 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Push-Out Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-push-out-casement-picture-4134/) | Wood | 0.14 | 0.10 | 2,719 |
| [**JELD-WEN, inc.** — Siteline Clad Wood (W-5500) Fixed Direct Set Geo](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-w-5500-fixed-direct-set-geo-413384/) | Wood | 0.14 | 0.13 | 4,582 |
| [**Weather Shield Mfg., Inc.** — 630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/) | Wood | 0.14 | 0.13 | 5,555 |

## What other certified series does Lepage Millwork produce?

Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [Fixed XL Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-fixed-xl-hung-413516/)

U-Factor 0.15–0.32 · 154 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-fixed-xl-hung-413516/)

Picture WindowMin U 0.16

### [Wood Fixed Casement C-100](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-fixed-casement-c-100-413518/)

U-Factor 0.16–0.32 · 282 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-fixed-casement-c-100-413518/)

Sliding Patio DoorMin U 0.17

### [Lift & Slide Door](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-lift-slide-door-413514/)

U-Factor 0.17–0.28 · 165 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-lift-slide-door-413514/)

Double HungMin U 0.17

### [XL-300 & XL-200 Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-300-xl-200-hung-413515/)

U-Factor 0.17–0.32 · 108 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-300-xl-200-hung-413515/)

Sliding Patio DoorMin U 0.18

### [MultiSlide Patio Door (Wood and Clad)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-multislide-patio-door-wood-and-clad-413520/)

U-Factor 0.18–0.28 · 132 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-multislide-patio-door-wood-and-clad-413520/)

Swinging Entry Door (Double)Min U 0.19

### [Bi-Fold Door](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-bi-fold-door-413513/)

U-Factor 0.19–0.28 · 122 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-bi-fold-door-413513/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork Wood Direct Set (TF-100) appear below.

### What U-Factor and SHGC range does Lepage Millwork Wood Direct Set (TF-100) achieve?

Lepage Millwork Wood Direct Set (TF-100) spans 90 certified configurations with U-Factors between 0.14 and 0.32 and SHGC values from 0.19 to 0.60. Ranked #72 of 1,352 Window families, it carries 27 Most Efficient options.

### Does Lepage Millwork Wood Direct Set (TF-100) qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 46 compliant Northern packages inside Wood Direct Set (TF-100), reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### How do you calculate winter heat conduction for Lepage Millwork Wood Direct Set (TF-100)?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Wood Direct Set (TF-100) at U 0.14 conducts 84.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Lepage Millwork Wood Direct Set (TF-100) for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Direct Set (TF-100) options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in Wood Direct Set (TF-100)?

Across Northern, North-Central, South-Central, Southern, 42 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Lepage Millwork Wood Direct Set (TF-100), while total line SHGC reaches 0.60 in colder packages.

### Which package tier in Wood Direct Set (TF-100) holds Most Efficient recognition?

No. Exactly 27 of 90 configurations (30.0%) earn ENERGY STAR Most Efficient status in Wood Direct Set (TF-100); the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Wood Direct Set (TF-100)?

Any Wood Direct Set (TF-100) purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify Wood Direct Set (TF-100) glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code LEP and product line LEP-M-77, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lepage Millwork Wood Direct Set (TF-100) come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)