title: "Lepage Millwork XL-100 Hung Specs (U 0.24) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-100-hung-413512/
description: "Lepage Millwork XL-100 Hung (LEP-M-53, Double Hung, Wood): U-Factor 0.24-0.27, SHGC 0.17-0.48, 16 options across 4 ENERGY STAR zones. Verified against."
---

Window · Wood Frame NFRC LEP · Product Line LEP-M-53

# Lepage Millwork — XL-100 Hung · Double Hung

Across 10 Lepage Millwork certified families, XL-100 Hung supplies 16 Double Hung configurations starting at 0.24 U-Factor and 0.17 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.27 U-Factor and 0.48 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.17-0.48

- **Certified Options** : 16

- **Category Standing** : #1,034 of 1,352

## How does Lepage Millwork XL-100 Hung compare thermally against Window peers?

Lepage Millwork XL-100 Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), XL-100 Hung reaches 0.24 on its lowest-conductivity package — #280 of 408 in Wood, tied with 38 others at 0.24, more insulating than 22.1% of Wood lines (+0.03 vs Wood peers). Pairing NFRC ID LEP across multi-pane fills shifts U-Factor from 0.27 down toward 0.24.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-10-24.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 16 certified glazing combinations for XL-100 Hung (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 8 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 8 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 8 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Harvey Industries, Inc.** — Majesty Picture Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-majesty-picture-window-413299/) | Wood | 0.24 | 0.17 | 95 |
| [**Lincoln Wood Products, Inc.** — Clad Hybrid Casement Studio (Transom) - Crank-Out & Push-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-hybrid-casement-studio-transom-crank/) | Wood | 0.24 | 0.17 | 137 |
| [**Marvin** — Elevate Awning Narrow Frame](https://ela-ecolandscapingassn.org/windows/models/marvin-elevate-awning-narrow-frame-413626/) | Wood | 0.24 | 0.17 | 146 |
| [**Lincoln Wood Products, Inc.** — Wood Casement Studio](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-casement-studio-414189/) | Wood | 0.24 | 0.17 | 149 |
| [**Marvin** — Elevate Casement Narrow Frame](https://ela-ecolandscapingassn.org/windows/models/marvin-elevate-casement-narrow-frame-413625/) | Wood | 0.24 | 0.17 | 149 |

## What other certified series does Lepage Millwork produce?

Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [Wood Direct Set (TF-100)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-direct-set-tf-100-413519/)

U-Factor 0.14–0.32 · 90 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-direct-set-tf-100-413519/)

Picture WindowMin U 0.15

### [Fixed XL Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-fixed-xl-hung-413516/)

U-Factor 0.15–0.32 · 154 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-fixed-xl-hung-413516/)

Picture WindowMin U 0.16

### [Wood Fixed Casement C-100](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-fixed-casement-c-100-413518/)

U-Factor 0.16–0.32 · 282 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-wood-fixed-casement-c-100-413518/)

Sliding Patio DoorMin U 0.17

### [Lift & Slide Door](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-lift-slide-door-413514/)

U-Factor 0.17–0.28 · 165 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-lift-slide-door-413514/)

Double HungMin U 0.17

### [XL-300 & XL-200 Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-300-xl-200-hung-413515/)

U-Factor 0.17–0.32 · 108 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-300-xl-200-hung-413515/)

Sliding Patio DoorMin U 0.18

### [MultiSlide Patio Door (Wood and Clad)](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-multislide-patio-door-wood-and-clad-413520/)

U-Factor 0.18–0.28 · 132 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-multislide-patio-door-wood-and-clad-413520/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork XL-100 Hung appear below.

### What U-Factor and SHGC range does Lepage Millwork XL-100 Hung achieve?

EPA ENERGY STAR v7.0 records 16 configurations for Lepage Millwork XL-100 Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Can homeowners install XL-100 Hung in cold Northern ENERGY STAR counties?

With a 0.24 minimum U-Factor, Lepage Millwork XL-100 Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 4 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### What conductive BTU/hr difference separates XL-100 Hung from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Lepage Millwork XL-100 Hung for a residential project?

Do not specify XL-100 Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on XL-100 Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in XL-100 Hung?

Yes. 8 Southern-certified options inside Lepage Millwork XL-100 Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.48 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 16 XL-100 Hung configurations ENERGY STAR Most Efficient?

No. Zero of the 16 configurations in Lepage Millwork XL-100 Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### Can homeowners claim Form 5695 credits on Lepage Millwork XL-100 Hung in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Lepage Millwork upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify XL-100 Hung glass specs on job sites?

Match the NFRC thermal sticker for code LEP and line LEP-M-53 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lepage Millwork XL-100 Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)