title: "Lindsay Windows 183 Picture Window Specs (U 0.22)"
url: https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-183-picture-window-413526/
description: "Lindsay Windows 183 Picture Window (LWW-K-6, Picture Window, Vinyl): U-Factor 0.22-0.32, SHGC 0.15-0.53, 102 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC LWW · Product Line LWW-K-6 ENERGY STAR Most Efficient Eligible

# Lindsay Windows — 183 Picture Window · Picture Window

Lindsay Windows engineered the 183 Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 102 glass-spacer combinations from 0.22 to 0.32 U-Factor and 0.15 to 0.53 SHGC. Relative to other Vinyl models tracked under NFRC LWW, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.15-0.53

- **Certified Options** : 102

- **Category Standing** : #831 of 1,352

## How does Lindsay Windows 183 Picture Window compare thermally against Window peers?

Lindsay Windows 183 Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 183 Picture Window spans 102 NFRC test records (LWW), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).

Climate coverage for Lindsay Windows 183 Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 2 configurations meet ENERGY STAR Most Efficient criteria while 22 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors LWW to 2025-12-02 certification (FENSTAR issued 2022-10-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 102 certified glazing combinations for 183 Picture Window (NFRC LWW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 22 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 34 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 53 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 68 packages (2 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Burris Windows** — TectView AC Picture](https://ela-ecolandscapingassn.org/windows/models/burris-windows-tectview-ac-picture-413090/) | Vinyl | 0.22 | 0.12 | 110 |
| [**Northeast Building Products Corporation** — Pro Series Plus Double Slider](https://ela-ecolandscapingassn.org/windows/models/northeast-building-products-corporation-pro-series-plus-double-slide/) | Vinyl | 0.22 | 0.17 | 89 |
| [**MGM Industries** — 8017 Sloped Sill Picture](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-8017-sloped-sill-picture-413728/) | Vinyl | 0.22 | 0.17 | 75 |
| [**Interstate Building Materials, Inc.** — 145/5000/5100/5200 Direct Set Picture Window](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-145-5000-5100-5200-direct-set-pict/) | Vinyl | 0.22 | 0.19 | 130 |
| [**NT Window, Inc.** — E150-Executive, N150-Construction Pro, X150-Energy Master, H150-Tradition, W150-Presidential, P150-solar Pro Picture Window](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-e150-executive-n150-construction-pro-x150-energy-maste/) | Vinyl | 0.22 | 0.13 | 132 |

## What other certified series does Lindsay Windows produce?

Compare other active Lindsay Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.16

### [Pinnacle / Healthy Picture Window](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-pinnacle-healthy-picture-window-413529/)

U-Factor 0.16–0.28 · 336 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-pinnacle-healthy-picture-window-413529/)

Picture WindowMin U 0.17

### [ClimateSmart / SunView / CrownView Picture Window](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-picture-window-413531/)

U-Factor 0.17–0.29 · 498 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-picture-window-413531/)

Picture WindowMin U 0.17

### [ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-fixe/)

U-Factor 0.17–0.28 · 156 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-fixe/)

Double HungMin U 0.17

### [Pinnacle / Healthy Double Hung](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-pinnacle-healthy-double-hung-413530/)

U-Factor 0.17–0.29 · 1,344 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-pinnacle-healthy-double-hung-413530/)

Awning (Projected)Min U 0.18

### [ClimateSmart / SunView / CrownView / Pinnacle / Healthy Awning](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-awni/)

U-Factor 0.18–0.28 · 304 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-awni/)

Casement WindowsMin U 0.18

### [ClimateSmart / SunView / CrownView / Pinnacle / Healthy Casement](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-case/)

U-Factor 0.18–0.28 · 308 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-case/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lindsay Windows 183 Picture Window appear below.

### How well does 183 Picture Window by Lindsay Windows insulate relative to Window benchmarks?

Testing puts Lindsay Windows 183 Picture Window at rank #831 of 1,352 Window entries with U 0.22 to 0.32 across 102 configurations. Solar heat gain ranges between 0.15 and 0.53 across Northern, North-Central, South-Central, Southern.

### How does Lindsay Windows 183 Picture Window satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 22 compliant Northern packages inside 183 Picture Window, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### What conductive BTU/hr difference separates 183 Picture Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Lindsay Windows 183 Picture Window?

Do not specify 183 Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 183 Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in 183 Picture Window?

Yes. 68 Southern-certified options inside Lindsay Windows 183 Picture Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.53 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 102 183 Picture Window configurations ENERGY STAR Most Efficient?

EPA lists 2 Most Efficient options (2.0% share) inside Lindsay Windows 183 Picture Window, out of 102 total Version 7.0 entries.

### Do 2026 183 Picture Window installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 183 Picture Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do you cross-check NFRC LWW and product line LWW-K-6 on delivery?

Inspectors match the temporary NFRC sticker (U 0.22-0.32, SHGC 0.15-0.53) against permit drawings for line LWW-K-6. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lindsay Windows 183 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)