title: "Marvin Elevate Awning Narrow Frame Specs (U 0.24)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-elevate-awning-narrow-frame-413626/
description: "Marvin Elevate Awning Narrow Frame (MAR-N-432, Awning (Projected), Wood): U-Factor 0.24-0.32, SHGC 0.17-0.22, 146 options across 3 ENERGY STAR zones."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-432

# Marvin — Elevate Awning Narrow Frame · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 146 variants inside Marvin Elevate Awning Narrow Frame, combining Wood frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.17 to 0.22. Qualifying for North-Central, South-Central, Southern, this Awning, Projected family places #1,034 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.17-0.22

- **Certified Options** : 146

- **Category Standing** : #1,034 of 1,352

## How does Marvin Elevate Awning Narrow Frame compare thermally against Window peers?

Marvin Elevate Awning Narrow Frame achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Elevate Awning Narrow Frame standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.03 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.17 to 0.22) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-04-24. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 146 certified glazing combinations for Elevate Awning Narrow Frame (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 36 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 104 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 146 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Lincoln Wood Products, Inc.** — Wood Casement Studio](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-casement-studio-414189/) | Wood | 0.24 | 0.17 | 149 |
| [**Lincoln Wood Products, Inc.** — Clad Hybrid Casement Studio (Transom) - Crank-Out & Push-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-hybrid-casement-studio-transom-crank/) | Wood | 0.24 | 0.17 | 137 |
| [**Harvey Industries, Inc.** — Majesty Picture Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-majesty-picture-window-413299/) | Wood | 0.24 | 0.17 | 95 |
| [**Lepage Millwork** — XL-100 Hung](https://ela-ecolandscapingassn.org/windows/models/lepage-millwork-xl-100-hung-413512/) | Wood | 0.24 | 0.17 | 16 |
| [**Andersen Corporation** — 400 Series Woodwright Curved-Top Hung Full-Frame Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-woodwright-curved-top-hung-full-fram/) | Wood | 0.24 | 0.15 | 300 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Elevate Awning Narrow Frame appear below.

### Where does Marvin Elevate Awning Narrow Frame stand thermally among ENERGY STAR Window lines?

Built with Wood framing in Projected Awning (PRAW) style, Marvin Elevate Awning Narrow Frame offers 146 Version 7.0 configurations from U 0.24 up to 0.32, posting +0.04 against the Window median of 0.20 with 0 Most Efficient picks.

### How does Marvin Elevate Awning Narrow Frame satisfy Version 7.0 Northern criteria?

No—with 0 Northern packages and a 0.24 thermal floor, Marvin Elevate Awning Narrow Frame targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

### What conductive BTU/hr difference separates Elevate Awning Narrow Frame from the 0.22 Northern rule?

Using NFRC MAR U-Factor 0.24, a 15 sq ft Projected Awning (PRAW) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

### Which situations make Elevate Awning Narrow Frame the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Elevate Awning Narrow Frame options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### Does Elevate Awning Narrow Frame meet Southern hot-climate SHGC caps (<= 0.23)?

Across North-Central, South-Central, Southern, 146 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Elevate Awning Narrow Frame, while total line SHGC reaches 0.22 in colder packages.

### Are all 146 Elevate Awning Narrow Frame configurations ENERGY STAR Most Efficient?

Zero glazing builds inside Elevate Awning Narrow Frame's 146 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What federal compliance checks govern 2026 Elevate Awning Narrow Frame window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Elevate Awning Narrow Frame installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered Marvin Elevate Awning Narrow Frame units match permits?

Match the NFRC thermal sticker for code MAR and line MAR-N-432 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Elevate Awning Narrow Frame come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)