Window · Wood Frame NFRC MAR · Product Line MAR-N-250 ENERGY STAR Most Efficient Eligible

# Marvin — Elevate Casement · Casement Windows

Marvin Elevate Casement is a Casement Windows assembly with a Wood frame that reaches a minimum U-Factor of 0.18 across 678 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #477 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.45.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.11-0.45

- **Certified Options** : 678

- **Category Standing** : #477 of 1,352

## How does Marvin Elevate Casement compare thermally against Window peers?

Marvin Elevate Casement achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Elevate Casement spans 678 NFRC test records (MAR), ranking #477 of 1,352 Window families (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%). Its 0.18 thermal floor compares at -0.03 against the Wood median (0.21).

Regional qualification covers Northern, North-Central, South-Central, Southern. 140 configurations meet ENERGY STAR Most Efficient criteria while 154 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-02-26.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 678 certified glazing combinations for Elevate Casement (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 154 packages (56 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 278 packages (116 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 360 packages (80 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 542 packages (104 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**JELD-WEN, inc.** — Custom Clad Direct Set Geometric](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-clad-direct-set-geometric-413361/) | Wood | 0.18 | 0.13 | 1,453 |
| [**Sierra Pacific Windows** — H3 2.0 Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-h3-2-0-direct-set-414082/) | Wood | 0.18 | 0.11 | 1,846 |
| [**Andersen Corporation** — 400 Series Tilt-Wash Double-Hung Picture Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-picture-full-f/) | Wood | 0.18 | 0.13 | 2,122 |
| [**Weather Shield Mfg., Inc.** — 6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/) | Wood | 0.18 | 0.11 | 2,658 |
| [**Andersen Corporation** — A-Series Fixed Transom Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-fixed-transom-window-412947/) | Wood | 0.18 | 0.12 | 5,832 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Elevate Casement appear below.

### Where does Marvin Elevate Casement stand thermally among ENERGY STAR Window lines?

Marvin Elevate Casement spans 678 certified configurations with U-Factors between 0.18 and 0.32 and SHGC values from 0.11 to 0.45. Ranked #477 of 1,352 Window families, it carries 140 Most Efficient options.

### Can homeowners install Elevate Casement in cold Northern ENERGY STAR counties?

Yes, 154 packages satisfy Northern ENERGY STAR Version 7.0 rules in Elevate Casement. Pairing multi-pane insulation down to 0.18 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What conductive BTU/hr difference separates Elevate Casement from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip Marvin Elevate Casement and compare alternatives?

Do not specify Elevate Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Elevate Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Elevate Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 542 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Elevate Casement, while total line SHGC reaches 0.45 in colder packages.

### Does Elevate Casement carry EPA Most Efficient certification across its lineup?

No. Exactly 140 of 678 configurations (20.6%) earn ENERGY STAR Most Efficient status in Elevate Casement; the remaining standard v7.0 options pass base zone limits only.

### What federal compliance checks govern 2026 Elevate Casement window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Elevate Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do you cross-check NFRC MAR and product line MAR-N-250 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-250, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Elevate Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)