---
title: "Marvin Elevate Double Hung Specs (U 0.24) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-elevate-double-hung-413572/
description: "Marvin Elevate Double Hung (MAR-N-272, Double Hung, Wood): U-Factor 0.24-0.32, SHGC 0.13-0.47, 460 options across 4 ENERGY STAR zones. Verified against."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-272

# Marvin — Elevate Double Hung · Double Hung

Positioning #1,034/1,352 in certified Window, Marvin Elevate Double Hung pairs Wood frame construction with 460 glazing options rated between 0.13 and 0.47 SHGC across Northern, North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.24 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.13-0.47

- **Certified Options** : 460

- **Category Standing** : #1,034 of 1,352

## How does Marvin Elevate Double Hung compare thermally against Window peers?

Marvin Elevate Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Elevate Double Hung reaches 0.24 on its lowest-conductivity package — #280 of 408 in Wood, tied with 38 others at 0.24, more insulating than 22.1% of Wood lines (+0.03 vs Wood peers). Pairing NFRC ID MAR across multi-pane fills shifts U-Factor from 0.32 down toward 0.24.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 24 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2026-08-27.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 460 certified glazing combinations for Elevate Double Hung (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 24 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 92 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 256 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 428 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Pella Corporation** — Pella Architect Reserve Double Hung - Wood - Model 5](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-architect-reserve-double-hung-wood-model-5-4/) | Wood | 0.24 | 0.11 | 456 |
| [**Windsor Windows and Doors** — Pinnacle Clad Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-double-hung-picture-414394/) | Wood | 0.24 | 0.14 | 454 |
| [**Weather Shield Mfg., Inc.** — 8122 Double Hung](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8122-double-hung-414368/) | Wood | 0.24 | 0.11 | 485 |
| [**Andersen Corporation** — E-Series Fixed Casement Window - Direct-Set (1 Piece)](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-fixed-casement-window-direct-set-1-pie/) | Wood | 0.24 | 0.08 | 494 |
| [**Windsor Windows and Doors** — Revive Legend Win-Pac](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-legend-win-pac-414428/) | Wood | 0.24 | 0.11 | 494 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Elevate Double Hung appear below.

### How well does Elevate Double Hung by Marvin insulate relative to Window benchmarks?

Testing puts Marvin Elevate Double Hung at rank #1,034 of 1,352 Window entries with U 0.24 to 0.32 across 460 configurations. Solar heat gain ranges between 0.13 and 0.47 across Northern, North-Central, South-Central, Southern.

### Can homeowners install Elevate Double Hung in cold Northern ENERGY STAR counties?

With a 0.24 minimum U-Factor, Marvin Elevate Double Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 24 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### How much winter heat loss does Elevate Double Hung conduct across a 15 sq ft opening?

At U 0.24, a standard 3x5 ft (15 sq ft) Elevate Double Hung opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

### When should a buyer skip Marvin Elevate Double Hung and compare alternatives?

Do not specify Elevate Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Elevate Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in Elevate Double Hung?

Yes, Elevate Double Hung holds 428 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

### What glazing share inside Elevate Double Hung qualifies as Most Efficient?

All 460 Elevate Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Elevate Double Hung?

Any Elevate Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify Elevate Double Hung glass specs on job sites?

Match the NFRC thermal sticker for code MAR and line MAR-N-272 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Elevate Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
