---
title: "Marvin Essential Casement Specs (U 0.26) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-essential-casement-413606/
description: "Marvin Essential Casement (MAR-N-375, Casement Windows, Fiberglass): U-Factor 0.26-0.31, SHGC 0.18-0.23, 37 options across 2 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-375

# Marvin — Essential Casement · Casement Windows

Positioning #1,256/1,352 in certified Window, Marvin Essential Casement pairs Fiberglass frame construction with 37 glazing options rated between 0.18 and 0.23 SHGC across South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.26 to 0.31 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.18-0.23

- **Certified Options** : 37

- **Category Standing** : #1,256 of 1,352

## How does Marvin Essential Casement compare thermally against Window peers?

Marvin Essential Casement achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Marvin Essential Casement at rank #1,256 of 1,352 (tied with 35 others at 0.26, more insulating than 4.5% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.18-0.23 band.

Regional qualification covers South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Lifecycle documentation anchors MAR to 2024-02-29 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 156.0 BTU/hr conductive loss (+18.2% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 37 certified glazing combinations for Essential Casement (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 16 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 37 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Lincoln Wood Products, Inc.** — Wood Awning - Push-Out & Crank-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-awning-push-out-crank-out-414188/) | Wood | 0.26 | 0.15 | 37 |
| [**Lincoln Wood Products, Inc.** — Clad Hybrid Casement - Crank-Out & Push-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-hybrid-casement-crank-out-push-out-41/) | Other | 0.26 | 0.16 | 38 |
| [**Comfort View Products, LLC** — 1920 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/comfort-view-products-llc-1920-horizontal-slider-413125/) | Vinyl | 0.26 | 0.20 | 33 |
| [**Lincoln Wood Products, Inc.** — Wood French Casement](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-french-casement-414194/) | Wood | 0.26 | 0.16 | 33 |
| [**Lincoln Wood Products, Inc.** — Wood Casement - Crank-Out & Push-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-wood-casement-crank-out-push-out-414187/) | Other | 0.26 | 0.15 | 44 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Essential Casement appear below.

### What thermal performance numbers separate Marvin Essential Casement from peers?

Marvin Essential Casement spans 37 certified configurations with U-Factors between 0.26 and 0.31 and SHGC values from 0.18 to 0.23. Ranked #1,256 of 1,352 Window families, it carries 0 Most Efficient options.

### How does Marvin Essential Casement satisfy Version 7.0 Northern criteria?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.26). Focus on South-Central, Southern glazing applications where SHGC 0.18-0.23 manages cooling loads.

### How much winter heat loss does Essential Casement conduct across a 15 sq ft opening?

Using NFRC MAR U-Factor 0.26, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

### Who should NOT choose Marvin Essential Casement for a residential project?

Do not specify Essential Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Essential Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Essential Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 37 Essential Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.18 rather than higher 0.23 glass.

### Are all 37 Essential Casement configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 37 Essential Casement options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What federal compliance checks govern 2026 Essential Casement window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify Essential Casement after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.26-0.31, SHGC 0.18-0.23) against permit drawings for line MAR-N-375. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Essential Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
