title: "Marvin Essential Casement Picture Specs (U 0.23)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-essential-casement-picture-413607/
description: "Marvin Essential Casement Picture (MAR-N-376, Picture Window, Fiberglass): U-Factor 0.23-0.32, SHGC 0.18-0.23, 316 options across 3 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-376

# Marvin — Essential Casement Picture · Picture Window

EPA ENERGY STAR Version 7.0 certifies 316 variants inside Marvin Essential Casement Picture, combining Fiberglass frame construction with U-Factors spanning 0.23 to 0.32 and SHGC 0.18 to 0.23. Qualifying for North-Central, South-Central, Southern, this Picture Window family places #936 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Fiberglass peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.18-0.23

- **Certified Options** : 316

- **Category Standing** : #936 of 1,352

## How does Marvin Essential Casement Picture compare thermally against Window peers?

Marvin Essential Casement Picture achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Essential Casement Picture standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-03-05 licensing and 2024-02-29 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 316 certified glazing combinations for Essential Casement Picture (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 76 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 216 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 316 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Pella Corporation** — Impervia Double Hung](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-double-hung-413891/) | Fiberglass | 0.23 | 0.13 | 450 |
| [**Pella Corporation** — Impervia Single Hung](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-single-hung-413887/) | Fiberglass | 0.23 | 0.12 | 574 |
| [**Pella Corporation** — Impervia Sliding Window](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-sliding-window-413888/) | Fiberglass | 0.23 | 0.12 | 670 |
| [**Milgard Manufacturing, Inc.** — 3644/3664 Panel Set Transom Inswing](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3644-3664-panel-set-transom-inswing-413753/) | Fiberglass | 0.23 | 0.09 | 2,958 |
| [**Milgard Manufacturing, Inc.** — 3647/3667 Outswing Panel Glazed Transom](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3647-3667-outswing-panel-glazed-transom-41/) | Fiberglass | 0.23 | 0.09 | 3,017 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Essential Casement Picture appear below.

### How efficient is Marvin Essential Casement Picture compared with peer Window models?

Testing puts Marvin Essential Casement Picture at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 316 configurations. Solar heat gain ranges between 0.18 and 0.23 across North-Central, South-Central, Southern.

### Can homeowners install Essential Casement Picture in cold Northern ENERGY STAR counties?

Marvin Essential Casement Picture holds zero Northern Zone qualifications (min U 0.23). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### What conductive BTU/hr difference separates Essential Casement Picture from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Marvin Essential Casement Picture for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Essential Casement Picture options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Does Essential Casement Picture meet Southern hot-climate SHGC caps (<= 0.23)?

Across North-Central, South-Central, Southern, 316 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Essential Casement Picture, while total line SHGC reaches 0.23 in colder packages.

### What glazing share inside Essential Casement Picture qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 316 Essential Casement Picture options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Essential Casement Picture?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Essential Casement Picture installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### Where are NFRC and IGCC identification marks located on Essential Casement Picture?

Verify NFRC ID MAR and series MAR-N-376 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Essential Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)