---
title: "Marvin Essential Double Hung Picture Specs (U 0.23)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-essential-double-hung-picture-413602/
description: "Marvin Essential Double Hung Picture (MAR-N-362, Picture Window, Fiberglass): U-Factor 0.23-0.32, SHGC 0.20-0.23, 101 options across 3 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-362

# Marvin — Essential Double Hung Picture · Picture Window

Positioning #936/1,352 in certified Window, Marvin Essential Double Hung Picture pairs Fiberglass frame construction with 101 glazing options rated between 0.20 and 0.23 SHGC across North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.23 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.20-0.23

- **Certified Options** : 101

- **Category Standing** : #936 of 1,352

## How does Marvin Essential Double Hung Picture compare thermally against Window peers?

Marvin Essential Double Hung Picture achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Essential Double Hung Picture is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Fiberglass frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.32.

Mapping NFRC SHGC values (0.20 to 0.23) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.20 lowers cooling load.

Lifecycle documentation anchors MAR to 2024-04-24 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 101 certified glazing combinations for Essential Double Hung Picture (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 24 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 64 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 101 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Pella Corporation** — Impervia Double Hung](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-double-hung-413891/) | Fiberglass | 0.23 | 0.13 | 450 |
| [**Pella Corporation** — Impervia Single Hung](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-single-hung-413887/) | Fiberglass | 0.23 | 0.12 | 574 |
| [**Pella Corporation** — Impervia Sliding Window](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-impervia-sliding-window-413888/) | Fiberglass | 0.23 | 0.12 | 670 |
| [**Milgard Manufacturing, Inc.** — 3644/3664 Panel Set Transom Inswing](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3644-3664-panel-set-transom-inswing-413753/) | Fiberglass | 0.23 | 0.09 | 2,958 |
| [**Milgard Manufacturing, Inc.** — 3647/3667 Outswing Panel Glazed Transom](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3647-3667-outswing-panel-glazed-transom-41/) | Fiberglass | 0.23 | 0.09 | 3,017 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Essential Double Hung Picture appear below.

### How efficient is Marvin Essential Double Hung Picture compared with peer Window models?

Built with Fiberglass framing in Fixed Window (FIXD) style, Marvin Essential Double Hung Picture offers 101 Version 7.0 configurations from U 0.23 up to 0.32, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

### Is Essential Double Hung Picture approved for Northern Zone heating climates?

Marvin Essential Double Hung Picture holds zero Northern Zone qualifications (min U 0.23). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### What conductive BTU/hr difference separates Essential Double Hung Picture from the 0.22 Northern rule?

Using NFRC MAR U-Factor 0.23, a 15 sq ft Fixed Window (FIXD) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

### What are the practical limitations of specifying Essential Double Hung Picture?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Essential Double Hung Picture options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in Essential Double Hung Picture?

Exactly 101 Essential Double Hung Picture options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.20 rather than higher 0.23 glass.

### Are all 101 Essential Double Hung Picture configurations ENERGY STAR Most Efficient?

All 101 Essential Double Hung Picture listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Do 2026 Essential Double Hung Picture installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do you cross-check NFRC MAR and product line MAR-N-362 on delivery?

Verify NFRC ID MAR and series MAR-N-362 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Essential Double Hung Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
