title: "Marvin Infinity Full Frame/Insert Casements Specs (U 0.19)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-infinity-full-frame-insert-casements-413575/
description: "Marvin Infinity Full Frame/Insert Casements (MAR-N-309, Casement Windows, Fiberglass): U-Factor 0.19-0.32, SHGC 0.12-0.30, 540 options across 4 ENERGY STAR."
---

Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-309 ENERGY STAR Most Efficient Eligible

# Marvin — Infinity Full Frame/Insert Casements · Casement Windows

Marvin Infinity Full Frame/Insert Casements is a Casement Windows assembly with a Fiberglass frame that reaches a minimum U-Factor of 0.19 across 540 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #564 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.30.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.12-0.30

- **Certified Options** : 540

- **Category Standing** : #564 of 1,352

## How does Marvin Infinity Full Frame/Insert Casements compare thermally against Window peers?

Marvin Infinity Full Frame/Insert Casements achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 105 certified Marvin series, this Casement Windows offers a 0.13 U-Factor adjustment span between 0.32 entry options and 0.19 top-performing glazing. Category standing is #564/1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%).

Mapping NFRC SHGC values (0.12 to 0.30) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 44 configurations meet ENERGY STAR Most Efficient criteria while 58 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors MAR to 2025-08-06 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 114.0 BTU/hr conductive loss (-13.6% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 540 certified glazing combinations for Infinity Full Frame/Insert Casements (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 58 packages (8 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 172 packages (16 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 228 packages (8 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 464 packages (36 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Milgard Manufacturing, Inc.** — 12210 Vertical Slider](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12210-vertical-slider-413786/) | Fiberglass | 0.19 | 0.09 | 6,177 |
| [**Milgard Manufacturing, Inc.** — 12110 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12110-horizontal-slider-413785/) | Fiberglass | 0.19 | 0.09 | 6,182 |
| [**Milgard Manufacturing, Inc.** — 12410 Awning Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12410-awning-window-413782/) | Fiberglass | 0.19 | 0.09 | 9,064 |
| [**Coeur D'Alene Window Company** — 3511 Awning Window](https://ela-ecolandscapingassn.org/windows/models/coeur-d-alene-window-company-3511-awning-window-413094/) | Vinyl | 0.19 | 0.10 | 540 |
| [**Coeur D'Alene Window Company** — 3411 Casement Window](https://ela-ecolandscapingassn.org/windows/models/coeur-d-alene-window-company-3411-casement-window-413093/) | Vinyl | 0.19 | 0.10 | 542 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Full Frame/Insert Casements appear below.

### How efficient is Marvin Infinity Full Frame/Insert Casements compared with peer Window models?

Across 540 tested NFRC glazing configurations, Marvin Infinity Full Frame/Insert Casements with Fiberglass framing and Casement Single-Vent (CSSV) style reaches a 0.19 minimum U-Factor and 0.12-0.30 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

### Is Infinity Full Frame/Insert Casements approved for Northern Zone heating climates?

Yes. 58 packages in Marvin Infinity Full Frame/Insert Casements clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### What BTU/hr heat transfer results from Infinity Full Frame/Insert Casements's 0.19 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Marvin Infinity Full Frame/Insert Casements?

Do not specify Infinity Full Frame/Insert Casements without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Full Frame/Insert Casements options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many Infinity Full Frame/Insert Casements glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 464 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Infinity Full Frame/Insert Casements, while total line SHGC reaches 0.30 in colder packages.

### Which package tier in Infinity Full Frame/Insert Casements holds Most Efficient recognition?

Only 44 options out of 540 (8.1%) meet tighter Most Efficient U-Factor and SHGC thresholds in Marvin Infinity Full Frame/Insert Casements, usually requiring triple-pane or upgraded Low-E coatings.

### Can homeowners claim Form 5695 credits on Marvin Infinity Full Frame/Insert Casements in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Infinity Full Frame/Insert Casements installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered Marvin Infinity Full Frame/Insert Casements units match permits?

Match the NFRC thermal sticker for code MAR and line MAR-N-309 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Full Frame/Insert Casements come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)