---
title: "Marvin Infinity Insert Double Hung Specs (U 0.20)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-infinity-insert-double-hung-413562/
description: "Marvin Infinity Insert Double Hung (MAR-N-244, Double Hung, Fiberglass): U-Factor 0.20-0.32, SHGC 0.12-0.32, 629 options across 4 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-244 ENERGY STAR Most Efficient Eligible

# Marvin — Infinity Insert Double Hung · Double Hung

Positioning #671/1,352 in certified Window, Marvin Infinity Insert Double Hung pairs Fiberglass frame construction with 629 glazing options rated between 0.12 and 0.32 SHGC across Northern, North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.20 to 0.32 U-Factor and the line includes 38 ENERGY STAR Most Efficient packages (6.0% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.20

- **SHGC Range** : 0.12-0.32

- **Certified Options** : 629

- **Category Standing** : #671 of 1,352

## How does Marvin Infinity Insert Double Hung compare thermally against Window peers?

Marvin Infinity Insert Double Hung achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Infinity Insert Double Hung standing at #671 of 1,352 certified Window product series, tied with 70 others at 0.20, more insulating than 45.2% of Window lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.01 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 38 configurations meet ENERGY STAR Most Efficient criteria while 56 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-05-14. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.20 conducts 120.0 BTU/hr (-12.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 629 certified glazing combinations for Infinity Insert Double Hung (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 56 packages (8 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 214 packages (16 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 296 packages (8 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 559 packages (30 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Advanced Window Corp.** — 5300 Double Hung](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-5300-double-hung-412864/) | Vinyl | 0.20 | 0.15 | 647 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Inswing Casement](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-inswing-casement-413473/) | Wood | 0.20 | 0.08 | 712 |
| [**Weather Shield Mfg., Inc.** — 8211/8216/1209/1210 Casement](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-casement-414357/) | Wood | 0.20 | 0.11 | 527 |
| [**Quaker Window Products** — V300 Sidelight](https://ela-ecolandscapingassn.org/windows/models/quaker-window-products-v300-sidelight-414000/) | Vinyl | 0.20 | 0.13 | 738 |
| [**Weather Shield Mfg., Inc.** — 8211/8216/1209/1210 Awning](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-awning-414358/) | Wood | 0.20 | 0.11 | 515 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Insert Double Hung appear below.

### How well does Infinity Insert Double Hung by Marvin insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 629 configurations for Marvin Infinity Insert Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.20 Window median. Only 38 options earn Most Efficient status.

### Does Marvin Infinity Insert Double Hung qualify for the ENERGY STAR Northern Zone?

Marvin Infinity Insert Double Hung supplies 56 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How does a 3x5 ft Infinity Insert Double Hung window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 120.0 BTU/hr on Infinity Insert Double Hung's lowest-U package (0.20), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What homeowner profiles are a poor match for Marvin Infinity Insert Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Insert Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### What Southern ENERGY STAR v7.0 options exist in Infinity Insert Double Hung?

Yes. 559 Southern-certified options inside Marvin Infinity Insert Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.32 SHGC on west-facing glass to avoid excess afternoon solar gain.

### How many Marvin Infinity Insert Double Hung variants earn ENERGY STAR Most Efficient?

No. Exactly 38 of 629 configurations (6.0%) earn ENERGY STAR Most Efficient status in Infinity Insert Double Hung; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Infinity Insert Double Hung?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Infinity Insert Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify Infinity Insert Double Hung after sticker removal?

Verify NFRC ID MAR and series MAR-N-244 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Insert Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
