---
title: "Marvin Infinity Sliding Glass Door Specs (U 0.23)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-infinity-sliding-glass-door-413604/
description: "Marvin Infinity Sliding Glass Door (MAR-N-373, Sliding Patio Door, Fiberglass): U-Factor 0.23-0.28, SHGC 0.15-0.23, 301 options across 4 ENERGY STAR zones."
---

Door · Fiberglass Frame NFRC MAR · Product Line MAR-N-373

# Marvin — Infinity Sliding Glass Door · Sliding Patio Door

Across 105 Marvin certified families, Infinity Sliding Glass Door supplies 301 Sliding Patio Door configurations starting at 0.23 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.23 SHGC. Its thermal floor ranks #162 of 268 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.15-0.23

- **Certified Options** : 301

- **Category Standing** : #162 of 268

## How does Marvin Infinity Sliding Glass Door compare thermally against Door peers?

Marvin Infinity Sliding Glass Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Infinity Sliding Glass Door standing at #162 of 268 certified Door product series, tied with 36 others at 0.23, more insulating than 26.1% of Door lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.15 to 0.23) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 168 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-04-24 and FENSTAR license 2019-03-05 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 301 certified glazing combinations for Infinity Sliding Glass Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 168 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 168 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 301 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 301 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Milgard Manufacturing, Inc.** — 3642/3662 Inswing Patio Door](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3642-3662-inswing-patio-door-413743/) | Fiberglass | 0.23 | 0.12 | 1,049 |
| [**Milgard Manufacturing, Inc.** — 3845/3865 Outswing Patio Door](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3845-3865-outswing-patio-door-413755/) | Fiberglass | 0.23 | 0.12 | 1,128 |
| [**Andersen Corporation** — Multi-Glide Patio Door - Clad Panels; Thermally Controlled Frame](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-multi-glide-patio-door-clad-panels-thermally-co/) | Fiberglass | 0.23 | 0.10 | 1,161 |
| [**Milgard Manufacturing, Inc.** — 3645/3665 Outswing Patio Door](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3645-3665-outswing-patio-door-413744/) | Fiberglass | 0.23 | 0.12 | 1,500 |
| [**Plastpro Inc.** — Plastpro Shaker & Craftsman Fiberglass Door](https://ela-ecolandscapingassn.org/windows/models/plastpro-inc-plastpro-shaker-craftsman-fiberglass-door-413826/) | Composite / Wood | 0.23 | 0.03 | 256 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Sliding Glass Door appear below.

### What U-Factor and SHGC range does Marvin Infinity Sliding Glass Door achieve?

Marvin Infinity Sliding Glass Door spans 301 certified configurations with U-Factors between 0.23 and 0.28 and SHGC values from 0.15 to 0.23. Ranked #162 of 268 Door families, it carries 0 Most Efficient options.

### Which glazing options in Marvin Infinity Sliding Glass Door meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above Infinity Sliding Glass Door's 0.23 minimum. However, 168 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### What BTU/hr heat transfer results from Infinity Sliding Glass Door's 0.23 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Marvin Infinity Sliding Glass Door for a residential project?

Do not specify Infinity Sliding Glass Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Sliding Glass Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Infinity Sliding Glass Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Infinity Sliding Glass Door holds 301 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

### Does Infinity Sliding Glass Door carry EPA Most Efficient certification across its lineup?

Infinity Sliding Glass Door holds zero Most Efficient entries across its 301 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Infinity Sliding Glass Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do you cross-check NFRC MAR and product line MAR-N-373 on delivery?

Verify NFRC ID MAR and series MAR-N-373 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Sliding Glass Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
