---
title: "Marvin Modern Awning Specs (U 0.21) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-modern-awning-413638/
description: "Marvin Modern Awning (MAR-N-447, Awning (Projected), Fiberglass): U-Factor 0.21-0.32, SHGC 0.11-0.40, 629 options across 4 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-447 ENERGY STAR Most Efficient Eligible

# Marvin — Modern Awning · Awning (Projected)

Marvin engineered the Modern Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 629 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.11 to 0.40 SHGC. Relative to other Fiberglass models tracked under NFRC MAR, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.11-0.40

- **Certified Options** : 629

- **Category Standing** : #742 of 1,352

## How does Marvin Modern Awning compare thermally against Window peers?

Marvin Modern Awning achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Modern Awning standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 12 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-08-01 and FENSTAR license 2019-03-05 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 629 certified glazing combinations for Modern Awning (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 14 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 79 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 224 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 602 packages (12 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**A Window, Inc.** — V-25 PW](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-25-pw-413080/) | Vinyl | 0.21 | 0.16 | 627 |
| [**A Window, Inc.** — V-31 PW](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v-31-pw-413085/) | Vinyl | 0.21 | 0.16 | 627 |
| [**Windsor Windows and Doors** — Legend Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-legend-casement-picture-414412/) | Wood | 0.21 | 0.15 | 608 |
| [**Weather Shield Mfg., Inc.** — 8123 Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8123-double-hung-picture-414372/) | Wood | 0.21 | 0.12 | 607 |
| [**Atrium Companies, Inc.** — 450/455/460/465 PW](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-450-455-460-465-pw-412877/) | Vinyl | 0.21 | 0.16 | 579 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Modern Awning appear below.

### Where does Marvin Modern Awning stand thermally among ENERGY STAR Window lines?

Marvin Modern Awning spans 629 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.11 to 0.40. Ranked #742 of 1,352 Window families, it carries 12 Most Efficient options.

### How does Marvin Modern Awning satisfy Version 7.0 Northern criteria?

Yes. 14 packages in Marvin Modern Awning clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

### What conductive BTU/hr difference separates Modern Awning from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Modern Awning at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Marvin Modern Awning for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Modern Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### How many Modern Awning glazing packages pass Southern solar-heat rules?

Yes. 602 Southern-certified options inside Marvin Modern Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.40 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Does Modern Awning carry EPA Most Efficient certification across its lineup?

EPA lists 12 Most Efficient options (1.9% share) inside Marvin Modern Awning, out of 629 total Version 7.0 entries.

### Can homeowners claim Form 5695 credits on Marvin Modern Awning in 2026?

Any Modern Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered Marvin Modern Awning units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-447, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Modern Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
