Door · Fiberglass Frame NFRC MAR · Product Line MAR-N-445 ENERGY STAR Most Efficient Eligible

# Marvin — Modern MultiSlide Door · Sliding Patio Door

Positioning #55/268 in certified Door, Marvin Modern MultiSlide Door pairs Fiberglass frame construction with 802 glazing options rated between 0.11 and 0.40 SHGC across Northern, North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.17 to 0.28 U-Factor and the line includes 138 ENERGY STAR Most Efficient packages (17.2% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.11-0.40

- **Certified Options** : 802

- **Category Standing** : #55 of 268

## How does Marvin Modern MultiSlide Door compare thermally against Door peers?

Marvin Modern MultiSlide Door achieves a 0.17 thermal floor across Door lines, placing #55 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Modern MultiSlide Door spans 802 NFRC test records (MAR), ranking #55 of 268 Door families (tied with 19 others at 0.17, more insulating than 72.4% of Door lines, top 27.6%). Its 0.17 thermal floor compares at -0.02 against the Fiberglass median (0.19).

Mapping NFRC SHGC values (0.11 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 138 configurations meet ENERGY STAR Most Efficient criteria while 568 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-03-05 licensing and 2024-04-24 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 802 certified glazing combinations for Modern MultiSlide Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 568 packages (52 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 568 packages (112 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 549 packages (64 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 549 packages (90 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Gilkey Window Company** — 5000 Series Fiberglass Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/gilkey-window-company-5000-series-fiberglass-sliding-patio-door-4132/) | Fiberglass | 0.17 | 0.07 | 23 |
| [**DRUTEX S.A.** — IGLO 5 Classic Tilt and Slide Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-tilt-and-slide-door-413156/) | Vinyl | 0.17 | 0.14 | 981 |
| [**Gerkin Windows and Doors** — 6400 Gliding Door](https://ela-ecolandscapingassn.org/windows/models/gerkin-windows-and-doors-6400-gliding-door-413267/) | Vinyl | 0.17 | 0.08 | 600 |
| [**Soft-Lite, LLC** — Kingsroyal Patio Door](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-kingsroyal-patio-door-414108/) | Vinyl | 0.17 | 0.12 | 485 |
| [**Therma-Tru Corporation** — Classic Craft Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-classic-craft-fiberglass-entry-door-414158/) | Wood | 0.17 | 0.01 | 378 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Modern MultiSlide Door appear below.

### How efficient is Marvin Modern MultiSlide Door compared with peer Door models?

Testing puts Marvin Modern MultiSlide Door at rank #55 of 268 Door entries with U 0.17 to 0.28 across 802 configurations. Solar heat gain ranges between 0.11 and 0.40 across Northern, North-Central, South-Central, Southern.

### Is Modern MultiSlide Door approved for Northern Zone heating climates?

Yes, 568 packages satisfy Northern ENERGY STAR Version 7.0 rules in Modern MultiSlide Door. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How much winter heat loss does Modern MultiSlide Door conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on Modern MultiSlide Door's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

### Which situations make Modern MultiSlide Door the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Modern MultiSlide Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many Modern MultiSlide Door glazing packages pass Southern solar-heat rules?

Exactly 549 Modern MultiSlide Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.40 glass.

### How many Marvin Modern MultiSlide Door variants earn ENERGY STAR Most Efficient?

EPA lists 138 Most Efficient options (17.2% share) inside Marvin Modern MultiSlide Door, out of 802 total Version 7.0 entries.

### What federal compliance checks govern 2026 Modern MultiSlide Door window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Modern MultiSlide Door glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-445, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Modern MultiSlide Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)