Door · Fiberglass Frame NFRC MAR · Product Line MAR-N-487 ENERGY STAR Most Efficient Eligible

# Marvin — Modern Sliding Door · Sliding Patio Door

Across 105 Marvin certified families, Modern Sliding Door supplies 452 Sliding Patio Door configurations starting at 0.20 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.40 SHGC. Its thermal floor ranks #116 of 268 category entries—0.01 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.20

- **SHGC Range** : 0.14-0.40

- **Certified Options** : 452

- **Category Standing** : #116 of 268

## How does Marvin Modern Sliding Door compare thermally against Door peers?

Marvin Modern Sliding Door achieves a 0.20 thermal floor across Door lines, placing #116 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Modern Sliding Door is 0.01 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Fiberglass frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.20-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 40 configurations meet ENERGY STAR Most Efficient criteria while 275 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-08-25 and FENSTAR license 2019-03-05 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 452 certified glazing combinations for Modern Sliding Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 275 packages (4 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 275 packages (8 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 327 packages (4 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 327 packages (36 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Milgard Manufacturing, Inc.** — 12610 Sliding Door](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12610-sliding-door-413788/) | Fiberglass | 0.20 | 0.11 | 1,627 |
| [**Seaway Manufacturing Corporation** — Prima Vista S-7500 Patio Door](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-prima-vista-s-7500-patio-door-41411/) | Vinyl | 0.20 | 0.11 | 456 |
| [**Therma-Tru Corporation** — Shaker Entry Door](https://ela-ecolandscapingassn.org/windows/models/therma-tru-corporation-shaker-entry-door-414157/) | Wood | 0.20 | 0.04 | 434 |
| [**Weather Shield Mfg., Inc.** — 8517 Contemporary Inswing Door](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8517-contemporary-inswing-door-414365/) | Wood | 0.20 | 0.13 | 503 |
| [**Western Architectural Openings** — 7650 Sliding Door](https://ela-ecolandscapingassn.org/windows/models/western-architectural-openings-7650-sliding-door-414381/) | Aluminum | 0.20 | 0.10 | 394 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Modern Sliding Door appear below.

### How efficient is Marvin Modern Sliding Door compared with peer Door models?

EPA ENERGY STAR v7.0 records 452 configurations for Marvin Modern Sliding Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.21 Door median. Only 40 options earn Most Efficient status.

### Which glazing options in Marvin Modern Sliding Door meet Northern climate limits?

Yes. 275 packages in Marvin Modern Sliding Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

### What BTU/hr heat transfer results from Modern Sliding Door's 0.20 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Which situations make Modern Sliding Door the wrong window or door choice?

Skip Modern Sliding Door if local historic preservation boards prohibit Fiberglass profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Modern Sliding Door options exceeding U 0.22.

### Can you install Marvin Modern Sliding Door in Southern or South-Central zones?

Warm-climate homeowners have 327 Southern-approved options within Modern Sliding Door spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### What glazing share inside Modern Sliding Door qualifies as Most Efficient?

Not every package qualifies: 40 of 452 Modern Sliding Door glazing builds earn Most Efficient recognition (8.8%), while other variants sit on the standard Version 7.0 tier.

### Can homeowners claim Form 5695 credits on Marvin Modern Sliding Door in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on Modern Sliding Door?

Confirm both the paper NFRC label and permanent corner glass etch match line MAR-N-487 and NFRC ID MAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Modern Sliding Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)