title: "Marvin Ultimate Casement Push Out Specs (U 0.23)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-casement-push-out-413590/
description: "Marvin Ultimate Casement Push Out (MAR-N-350, Casement Windows, Wood): U-Factor 0.23-0.32, SHGC 0.10-0.39, 12297 options across 3 ENERGY STAR zones."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-350

# Marvin — Ultimate Casement Push Out · Casement Windows

Across 105 Marvin certified families, Ultimate Casement Push Out supplies 12,297 Casement Windows configurations starting at 0.23 U-Factor and 0.10 SHGC for North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.39 SHGC. Its thermal floor ranks #936 of 1,352 category entries—0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.10-0.39

- **Certified Options** : 12,297

- **Category Standing** : #936 of 1,352

## How does Marvin Ultimate Casement Push Out compare thermally against Window peers?

Marvin Ultimate Casement Push Out achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Ultimate Casement Push Out standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.02 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.10 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2025-08-07. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12,297 certified glazing combinations for Ultimate Casement Push Out (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 214 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 2,024 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 12,247 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — E-Series Double-Hung Window - Full Frame](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-double-hung-window-full-frame-412992/) | Wood | 0.23 | 0.09 | 6,710 |
| [**Andersen Corporation** — A-Series Frenchwood® Patio Door Transom - Sash-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-frenchwood-patio-door-transom-sash-set/) | Wood | 0.23 | 0.11 | 3,861 |
| [**Andersen Corporation** — E-Series Awning/Push Out Awning Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-awning-push-out-awning-windows-412999/) | Wood | 0.23 | 0.13 | 3,764 |
| [**Andersen Corporation** — 200 Series Double-Hung Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-double-hung-fixed-specialty-windows/) | Wood | 0.23 | 0.14 | 1,727 |
| [**Andersen Corporation** — 400 Series Frenchwood® Patio Door Transom](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-frenchwood-patio-door-transom-412930/) | Wood | 0.23 | 0.10 | 1,676 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Casement Push Out appear below.

### Where does Marvin Ultimate Casement Push Out stand thermally among ENERGY STAR Window lines?

Marvin Ultimate Casement Push Out spans 12,297 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.10 to 0.39. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.

### Does Marvin Ultimate Casement Push Out qualify for the ENERGY STAR Northern Zone?

No—with 0 Northern packages and a 0.23 thermal floor, Marvin Ultimate Casement Push Out targets warmer North-Central, South-Central, Southern climates instead of cold Northern installations.

### What BTU/hr heat transfer results from Ultimate Casement Push Out's 0.23 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on Ultimate Casement Push Out's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What homeowner profiles are a poor match for Marvin Ultimate Casement Push Out?

Do not specify Ultimate Casement Push Out without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Casement Push Out options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Can you install Marvin Ultimate Casement Push Out in Southern or South-Central zones?

Exactly 12,247 Ultimate Casement Push Out options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.10 rather than higher 0.39 glass.

### Does Ultimate Casement Push Out carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside Ultimate Casement Push Out's 12,297 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### Do 2026 Ultimate Casement Push Out installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Ultimate Casement Push Out retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do building inspectors verify Ultimate Casement Push Out glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line MAR-N-350 and NFRC ID MAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Casement Push Out come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)