title: "Marvin Ultimate Casement Venting Picture Specs (U 0.16)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-casement-venting-picture-413609/
description: "Marvin Ultimate Casement Venting Picture (MAR-N-378, Picture Window, Wood): U-Factor 0.16-0.32, SHGC 0.11-0.45, 11988 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-378 ENERGY STAR Most Efficient Eligible

# Marvin — Ultimate Casement Venting Picture · Picture Window

Marvin engineered the Ultimate Casement Venting Picture Picture Window line for Northern, North-Central, South-Central, Southern, certifying 11,988 glass-spacer combinations from 0.16 to 0.32 U-Factor and 0.11 to 0.45 SHGC. Relative to other Wood models tracked under NFRC MAR, its minimum U-Factor is 0.05 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.11-0.45

- **Certified Options** : 11,988

- **Category Standing** : #250 of 1,352

## How does Marvin Ultimate Casement Venting Picture compare thermally against Window peers?

Marvin Ultimate Casement Venting Picture achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Ultimate Casement Venting Picture is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 976 configurations meet ENERGY STAR Most Efficient criteria while 998 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-04-24.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11,988 certified glazing combinations for Ultimate Casement Venting Picture (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 998 packages (470 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 4,779 packages (728 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 6,848 packages (402 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 9,610 packages (610 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-casement-fixed-412924/) | Wood | 0.16 | 0.14 | 3,248 |
| [**Sierra Pacific Windows** — Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/) | Wood | 0.16 | 0.10 | 2,962 |
| [**Andersen Corporation** — A-Series Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-specialty-windows-direct-set-412965/) | Wood | 0.16 | 0.16 | 2,333 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Push Out Awning MPL & SPL](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-push-out-awning-mpl-spl-413/) | Wood | 0.16 | 0.08 | 1,730 |
| [**Sierra Pacific Windows** — Clad Aspen Casement](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-casement-414080/) | Wood | 0.16 | 0.09 | 1,629 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Casement Venting Picture appear below.

### How well does Ultimate Casement Venting Picture by Marvin insulate relative to Window benchmarks?

Testing puts Marvin Ultimate Casement Venting Picture at rank #250 of 1,352 Window entries with U 0.16 to 0.32 across 11,988 configurations. Solar heat gain ranges between 0.11 and 0.45 across Northern, North-Central, South-Central, Southern.

### How does Marvin Ultimate Casement Venting Picture satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 998 Ultimate Casement Venting Picture packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from Ultimate Casement Venting Picture's 0.16 minimum U-Factor?

At U 0.16, a standard 3x5 ft (15 sq ft) Ultimate Casement Venting Picture opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

### When should a buyer skip Marvin Ultimate Casement Venting Picture and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Casement Venting Picture options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### How many Ultimate Casement Venting Picture glazing packages pass Southern solar-heat rules?

Exactly 9,610 Ultimate Casement Venting Picture options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.45 glass.

### Which package tier in Ultimate Casement Venting Picture holds Most Efficient recognition?

Not every package qualifies: 976 of 11,988 Ultimate Casement Venting Picture glazing builds earn Most Efficient recognition (8.1%), while other variants sit on the standard Version 7.0 tier.

### Can homeowners claim Form 5695 credits on Marvin Ultimate Casement Venting Picture in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do you cross-check NFRC MAR and product line MAR-N-378 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line MAR-N-378 and NFRC ID MAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Casement Venting Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)