title: "Marvin Ultimate Double Hung Picture G2 Specs (U 0.19)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-double-hung-picture-g2-413623/
description: "Marvin Ultimate Double Hung Picture G2 (MAR-N-427, Picture Window, Wood): U-Factor 0.19-0.32, SHGC 0.11-0.42, 3337 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-427 ENERGY STAR Most Efficient Eligible

# Marvin — Ultimate Double Hung Picture G2 · Picture Window

With a minimum U-Factor of 0.19—-0.01 compared against the 0.20 Window median—Marvin Ultimate Double Hung Picture G2 spans 3,337 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MAR, the Wood assembly includes 152 ENERGY STAR Most Efficient packages (4.6% of line) and offers SHGC packages between 0.11 and 0.42.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.11-0.42

- **Certified Options** : 3,337

- **Category Standing** : #564 of 1,352

## How does Marvin Ultimate Double Hung Picture G2 compare thermally against Window peers?

Marvin Ultimate Double Hung Picture G2 achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Ultimate Double Hung Picture G2 standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Wood profiles alone (median 0.21) shows -0.02 before selecting Low-E tiers.

Climate coverage for Marvin Ultimate Double Hung Picture G2 spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 152 configurations meet ENERGY STAR Most Efficient criteria while 181 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-08-07 and FENSTAR license 2019-03-05 inside EPA Version 7.0 tables. Heat transfer computes to 114.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,337 certified glazing combinations for Ultimate Double Hung Picture G2 (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 181 packages (42 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 968 packages (92 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,463 packages (64 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,905 packages (123 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — A-Series Frenchwood® Patio Door Transom - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-frenchwood-patio-door-transom-direct-s/) | Wood | 0.19 | 0.14 | 2,668 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Push-Out Awning](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-push-out-awning-413471/) | Wood | 0.19 | 0.09 | 2,516 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Push-Out Casement](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-push-out-casement-413470/) | Wood | 0.19 | 0.09 | 2,500 |
| [**JELD-WEN, inc.** — Custom Wood Casement](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-wood-casement-413356/) | Wood | 0.19 | 0.10 | 2,398 |
| [**Andersen Corporation** — E-Series Hinged Patio Door Sidelight-Inswing Direct Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-hinged-patio-door-sidelight-inswing-di/) | Wood | 0.19 | 0.12 | 2,304 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Double Hung Picture G2 appear below.

### What U-Factor and SHGC range does Marvin Ultimate Double Hung Picture G2 achieve?

Marvin Ultimate Double Hung Picture G2 spans 3,337 certified configurations with U-Factors between 0.19 and 0.32 and SHGC values from 0.11 to 0.42. Ranked #564 of 1,352 Window families, it carries 152 Most Efficient options.

### Which glazing options in Marvin Ultimate Double Hung Picture G2 meet Northern climate limits?

Cold-climate buyers get 181 compliant Northern packages inside Ultimate Double Hung Picture G2, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### How much winter heat loss does Ultimate Double Hung Picture G2 conduct across a 15 sq ft opening?

Using NFRC MAR U-Factor 0.19, a 15 sq ft Fixed Window (FIXD) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

### Which situations make Ultimate Double Hung Picture G2 the wrong window or door choice?

Skip Ultimate Double Hung Picture G2 if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Double Hung Picture G2 options exceeding U 0.22.

### Is Ultimate Double Hung Picture G2 suitable for sunbelt cooling-dominated homes?

Yes. 2,905 Southern-certified options inside Marvin Ultimate Double Hung Picture G2 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

### What glazing share inside Ultimate Double Hung Picture G2 qualifies as Most Efficient?

Not every package qualifies: 152 of 3,337 Ultimate Double Hung Picture G2 glazing builds earn Most Efficient recognition (4.6%), while other variants sit on the standard Version 7.0 tier.

### Can homeowners claim Form 5695 credits on Marvin Ultimate Double Hung Picture G2 in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify Ultimate Double Hung Picture G2 after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-427, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Double Hung Picture G2 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)