title: "Marvin Ultimate Double Hung / Single Hung Insert G2 Specs"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-double-hung-single-hung-insert-g2-413632/
description: "Marvin Ultimate Double Hung / Single Hung Insert G2 (MAR-N-441, Double Hung, Wood): U-Factor 0.20-0.32, SHGC 0.11-0.41, 2595 options across 4 ENERGY STAR."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-441 ENERGY STAR Most Efficient Eligible

# Marvin — Ultimate Double Hung / Single Hung Insert G2 · Double Hung

Marvin engineered the Ultimate Double Hung / Single Hung Insert G2 Double Hung line for Northern, North-Central, South-Central, Southern, certifying 2,595 glass-spacer combinations from 0.20 to 0.32 U-Factor and 0.11 to 0.41 SHGC. Relative to other Wood models tracked under NFRC MAR, its minimum U-Factor is 0.01 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.20

- **SHGC Range** : 0.11-0.41

- **Certified Options** : 2,595

- **Category Standing** : #671 of 1,352

## How does Marvin Ultimate Double Hung / Single Hung Insert G2 compare thermally against Window peers?

Marvin Ultimate Double Hung / Single Hung Insert G2 achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultimate Double Hung / Single Hung Insert G2 spans 2,595 NFRC test records (MAR), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at -0.01 against the Wood median (0.21).

Mapping NFRC SHGC values (0.11 to 0.41) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 65 configurations meet ENERGY STAR Most Efficient criteria while 116 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2024-04-02.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,595 certified glazing combinations for Ultimate Double Hung / Single Hung Insert G2 (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 116 packages (0 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 275 packages (6 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 830 packages (6 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,452 packages (65 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Casement Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-casement-window-412911/) | Wood | 0.20 | 0.14 | 1,184 |
| [**Andersen Corporation** — 400 Series Awning Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-awning-window-412912/) | Wood | 0.20 | 0.14 | 1,015 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Casement](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-casement-413457/) | Wood | 0.20 | 0.09 | 893 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Inswing Casement](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-inswing-casement-413473/) | Wood | 0.20 | 0.08 | 712 |
| [**Weather Shield Mfg., Inc.** — 8211/8216/1209/1210 Casement](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-casement-414357/) | Wood | 0.20 | 0.11 | 527 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Double Hung / Single Hung Insert G2 appear below.

### How well does Ultimate Double Hung / Single Hung Insert G2 by Marvin insulate relative to Window benchmarks?

Marvin Ultimate Double Hung / Single Hung Insert G2 spans 2,595 certified configurations with U-Factors between 0.20 and 0.32 and SHGC values from 0.11 to 0.41. Ranked #671 of 1,352 Window families, it carries 65 Most Efficient options.

### Can homeowners install Ultimate Double Hung / Single Hung Insert G2 in cold Northern ENERGY STAR counties?

Yes, 116 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultimate Double Hung / Single Hung Insert G2. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft Ultimate Double Hung / Single Hung Insert G2 window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip Marvin Ultimate Double Hung / Single Hung Insert G2 and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Double Hung / Single Hung Insert G2 options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Can you install Marvin Ultimate Double Hung / Single Hung Insert G2 in Southern or South-Central zones?

Yes. 2,452 Southern-certified options inside Marvin Ultimate Double Hung / Single Hung Insert G2 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.41 SHGC on west-facing glass to avoid excess afternoon solar gain.

### What glazing share inside Ultimate Double Hung / Single Hung Insert G2 qualifies as Most Efficient?

Within Ultimate Double Hung / Single Hung Insert G2, 2.5% (65 of 2,595) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### Do 2026 Ultimate Double Hung / Single Hung Insert G2 installations qualify for IRS Section 25C tax credits?

Any Ultimate Double Hung / Single Hung Insert G2 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### What permanent glass etch marks verify Ultimate Double Hung / Single Hung Insert G2 after sticker removal?

Match the NFRC thermal sticker for code MAR and line MAR-N-441 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Double Hung / Single Hung Insert G2 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)