title: "Marvin Ultimate Inswing French Door Transom G2 Specs"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-inswing-french-door-transom-g2-413646/
description: "Marvin Ultimate Inswing French Door Transom G2 (MAR-N-481, Picture Window, Wood): U-Factor 0.16-0.32, SHGC 0.10-0.41, 8525 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-481 ENERGY STAR Most Efficient Eligible

# Marvin — Ultimate Inswing French Door Transom G2 · Picture Window

With a minimum U-Factor of 0.16—-0.04 compared against the 0.20 Window median—Marvin Ultimate Inswing French Door Transom G2 spans 8,525 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MAR, the Wood assembly includes 652 ENERGY STAR Most Efficient packages (7.6% of line) and offers SHGC packages between 0.10 and 0.41.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.10-0.41

- **Certified Options** : 8,525

- **Category Standing** : #250 of 1,352

## How does Marvin Ultimate Inswing French Door Transom G2 compare thermally against Window peers?

Marvin Ultimate Inswing French Door Transom G2 achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Ultimate Inswing French Door Transom G2 standing at #250 of 1,352 certified Window product series, tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%. Comparing Wood profiles alone (median 0.21) shows -0.05 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 652 configurations meet ENERGY STAR Most Efficient criteria while 556 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors MAR to 2024-04-02 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 96.0 BTU/hr conductive loss (-27.3% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8,525 certified glazing combinations for Ultimate Inswing French Door Transom G2 (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 556 packages (280 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,876 packages (542 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 3,383 packages (366 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 7,845 packages (466 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-casement-fixed-412924/) | Wood | 0.16 | 0.14 | 3,248 |
| [**Sierra Pacific Windows** — Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-direct-set-414067/) | Wood | 0.16 | 0.10 | 2,962 |
| [**Andersen Corporation** — A-Series Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-specialty-windows-direct-set-412965/) | Wood | 0.16 | 0.16 | 2,333 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Push Out Awning MPL & SPL](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-push-out-awning-mpl-spl-413/) | Wood | 0.16 | 0.08 | 1,730 |
| [**Sierra Pacific Windows** — Clad Aspen Casement](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-casement-414080/) | Wood | 0.16 | 0.09 | 1,629 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Inswing French Door Transom G2 appear below.

### How efficient is Marvin Ultimate Inswing French Door Transom G2 compared with peer Window models?

Across 8,525 tested NFRC glazing configurations, Marvin Ultimate Inswing French Door Transom G2 with Wood framing and Fixed Window (FIXD) style reaches a 0.16 minimum U-Factor and 0.10-0.41 SHGC band. It places #250 among 1,352 Window series—top 26.7%.

### Which glazing options in Marvin Ultimate Inswing French Door Transom G2 meet Northern climate limits?

Yes, 556 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultimate Inswing French Door Transom G2. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft Ultimate Inswing French Door Transom G2 window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on Ultimate Inswing French Door Transom G2's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### When should a buyer skip Marvin Ultimate Inswing French Door Transom G2 and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Inswing French Door Transom G2 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many Ultimate Inswing French Door Transom G2 glazing packages pass Southern solar-heat rules?

Exactly 7,845 Ultimate Inswing French Door Transom G2 options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.10 rather than higher 0.41 glass.

### How many Marvin Ultimate Inswing French Door Transom G2 variants earn ENERGY STAR Most Efficient?

Within Ultimate Inswing French Door Transom G2, 7.6% (652 of 8,525) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### Can homeowners claim Form 5695 credits on Marvin Ultimate Inswing French Door Transom G2 in 2026?

Any Ultimate Inswing French Door Transom G2 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### What permanent glass etch marks verify Ultimate Inswing French Door Transom G2 after sticker removal?

Verify NFRC ID MAR and series MAR-N-481 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Inswing French Door Transom G2 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)