title: "Marvin Ultimate Wood Direct Glaze Round Top Specs (U 0.13)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/
description: "Marvin Ultimate Wood Direct Glaze Round Top (MAR-N-418, Picture Window, Wood): U-Factor 0.13-0.32, SHGC 0.12-0.60, 8590 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-418 ENERGY STAR Most Efficient Eligible

# Marvin — Ultimate Wood Direct Glaze Round Top · Picture Window

Across 105 Marvin certified families, Ultimate Wood Direct Glaze Round Top supplies 8,590 Picture Window configurations starting at 0.13 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.60 SHGC. Its thermal floor ranks #36 of 1,352 category entries—0.07 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.13

- **SHGC Range** : 0.12-0.60

- **Certified Options** : 8,590

- **Category Standing** : #36 of 1,352

## How does Marvin Ultimate Wood Direct Glaze Round Top compare thermally against Window peers?

Marvin Ultimate Wood Direct Glaze Round Top achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Marvin Ultimate Wood Direct Glaze Round Top at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.60 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 1,742 configurations meet ENERGY STAR Most Efficient criteria while 3,064 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-07-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.13 conducts 78.0 BTU/hr (-54.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8,590 certified glazing combinations for Ultimate Wood Direct Glaze Round Top (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 3,064 packages (414 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 5,510 packages (498 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 4,473 packages (246 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 5,647 packages (1,430 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Gardenaire Sliding Patio Door Sidelite](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-gardenaire-sliding-patio-do/) | Wood | 0.13 | 0.07 | 4,426 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Inswing Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-inswing-casement-picture-41/) | Wood | 0.13 | 0.09 | 1,123 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra XL Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-xl-casement-picture-413475/) | Wood | 0.13 | 0.10 | 1,118 |
| [**Wincore Window Company, LLC** — Plastpro Fiberglass Sidelite](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-plastpro-fiberglass-sidelite-414328/) | Steel / Vinyl / Wood | 0.13 | 0.00 | 7,791 |
| [**Plastpro Inc.** — Plastpro Fiberglass Sidelite](https://ela-ecolandscapingassn.org/windows/models/plastpro-inc-plastpro-fiberglass-sidelite-413825/) | Steel / Vinyl / Wood | 0.13 | 0.00 | 7,082 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

Picture WindowMin U 0.14

### [Ultimate Direct Glaze Narrow Frame Rectangle](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-narrow-frame-rectangle-413631/)

U-Factor 0.14–0.32 · 21,304 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-narrow-frame-rectangle-413631/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Direct Glaze Round Top appear below.

### Where does Marvin Ultimate Wood Direct Glaze Round Top stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 8,590 configurations for Marvin Ultimate Wood Direct Glaze Round Top covering Northern, North-Central, South-Central, Southern, dropping down to U 0.13 versus a 0.20 Window median. Only 1,742 options earn Most Efficient status.

### Which glazing options in Marvin Ultimate Wood Direct Glaze Round Top meet Northern climate limits?

Yes, 3,064 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultimate Wood Direct Glaze Round Top. Pairing multi-pane insulation down to 0.13 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft Ultimate Wood Direct Glaze Round Top window perform under a 40 deg F temperature drop?

Using NFRC MAR U-Factor 0.13, a 15 sq ft Fixed Window (FIXD) assembly conducts 78.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-54.0 BTU/hr margin).

### Who should NOT choose Marvin Ultimate Wood Direct Glaze Round Top for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Direct Glaze Round Top options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### What Southern ENERGY STAR v7.0 options exist in Ultimate Wood Direct Glaze Round Top?

Across Northern, North-Central, South-Central, Southern, 5,647 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Ultimate Wood Direct Glaze Round Top, while total line SHGC reaches 0.60 in colder packages.

### Does Ultimate Wood Direct Glaze Round Top carry EPA Most Efficient certification across its lineup?

No. Exactly 1,742 of 8,590 configurations (20.3%) earn ENERGY STAR Most Efficient status in Ultimate Wood Direct Glaze Round Top; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Ultimate Wood Direct Glaze Round Top?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Ultimate Wood Direct Glaze Round Top installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered Marvin Ultimate Wood Direct Glaze Round Top units match permits?

Verify NFRC ID MAR and series MAR-N-418 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Direct Glaze Round Top come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)