title: "Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-picture-1-5-8-inch-sash-413557/
description: "Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash (MAR-N-70, Picture Window, Wood): U-Factor 0.23-0.32, SHGC 0.11-0.30, 1700 options across 3 ENERGY."
---

Window · Wood Frame NFRC MAR · Product Line MAR-N-70

# Marvin — Ultimate Wood Double Hung Picture 1 5/8 inch Sash · Picture Window

With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash spans 1,700 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MAR, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.11 and 0.30.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.11-0.30

- **Certified Options** : 1,700

- **Category Standing** : #936 of 1,352

## How does Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash compare thermally against Window peers?

Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Ultimate Wood Double Hung Picture 1 5/8 inch Sash reaches 0.23 on its lowest-conductivity package — #246 of 408 in Wood, tied with 33 others at 0.23, more insulating than 31.6% of Wood lines (+0.02 vs Wood peers). Pairing NFRC ID MAR across multi-pane fills shifts U-Factor from 0.32 down toward 0.23.

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-03-05 licensing and 2024-08-08 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,700 certified glazing combinations for Ultimate Wood Double Hung Picture 1 5/8 inch Sash (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 514 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 987 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,458 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Frenchwood® Patio Door Transom](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-frenchwood-patio-door-transom-412930/) | Wood | 0.23 | 0.10 | 1,676 |
| [**Andersen Corporation** — 200 Series Double-Hung Fixed/Specialty Windows](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-double-hung-fixed-specialty-windows/) | Wood | 0.23 | 0.14 | 1,727 |
| [**Andersen Corporation** — 400 Series Specialty Windows - Springline®](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-windows-springline-412921/) | Wood | 0.23 | 0.15 | 1,657 |
| [**Andersen Corporation** — A-Series Frenchwood® Patio Door Sidelight](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-frenchwood-patio-door-sidelight-412950/) | Wood | 0.23 | 0.10 | 799 |
| [**Windsor Windows and Doors** — Legend Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-legend-double-hung-transom-414401/) | Wood | 0.23 | 0.10 | 777 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash appear below.

### Where does Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash stand thermally among ENERGY STAR Window lines?

Testing puts Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 1,700 configurations. Solar heat gain ranges between 0.11 and 0.30 across North-Central, South-Central, Southern.

### How does Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash satisfy Version 7.0 Northern criteria?

No. Because Ultimate Wood Double Hung Picture 1 5/8 inch Sash reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across North-Central, South-Central, Southern cooling or mixed markets.

### How do you calculate winter heat conduction for Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

Using NFRC MAR U-Factor 0.23, a 15 sq ft Fixed Window (FIXD) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

### What homeowner profiles are a poor match for Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Double Hung Picture 1 5/8 inch Sash options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is Ultimate Wood Double Hung Picture 1 5/8 inch Sash suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 1,458 Southern-approved options within Ultimate Wood Double Hung Picture 1 5/8 inch Sash spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 1,700 Ultimate Wood Double Hung Picture 1 5/8 inch Sash configurations ENERGY STAR Most Efficient?

All 1,700 Ultimate Wood Double Hung Picture 1 5/8 inch Sash listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Ultimate Wood Double Hung Picture 1 5/8 inch Sash retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

Match the NFRC thermal sticker for code MAR and line MAR-N-70 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)