title: "Marvin Ultimate Wood Inswing French Door Specs (U 0.26)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-inswing-french-door-413613/
description: "Marvin Ultimate Wood Inswing French Door (MAR-N-393, Swinging Entry Door (Double), Wood): U-Factor 0.26-0.28, SHGC 0.10-0.24, 1164 options across 4 ENERGY."
---

Door · Wood Frame NFRC MAR · Product Line MAR-N-393

# Marvin — Ultimate Wood Inswing French Door · Swinging Entry Door (Double)

Across 105 Marvin certified families, Ultimate Wood Inswing French Door supplies 1,164 Swinging Entry Door, Double configurations starting at 0.26 U-Factor and 0.10 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.24 SHGC. Its thermal floor ranks #233 of 268 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.10-0.24

- **Certified Options** : 1,164

- **Category Standing** : #233 of 268

## How does Marvin Ultimate Wood Inswing French Door compare thermally against Door peers?

Marvin Ultimate Wood Inswing French Door achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultimate Wood Inswing French Door spans 1,164 NFRC test records (MAR), ranking #233 of 268 Door families (tied with 15 others at 0.26, more insulating than 7.5% of Door lines). Its 0.26 thermal floor compares at +0.05 against the Wood median (0.21).

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 216 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-03-05 licensing and 2025-08-27 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,164 certified glazing combinations for Ultimate Wood Inswing French Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 216 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 216 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 1,152 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,152 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — Residential Wood Entry Door - Inswing](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-residential-wood-entry-door-inswing-412978/) | Wood | 0.26 | 0.09 | 1,315 |
| [**Andersen Corporation** — E-Series Hinged Outswing Patio Door](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-e-series-hinged-outswing-patio-door-412991/) | Wood | 0.26 | 0.10 | 234 |
| [**Weather Shield Mfg., Inc.** — 6510/6610 Swing Door](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6510-6610-swing-door-414363/) | Wood | 0.26 | 0.11 | 207 |
| [**Windsor Windows and Doors** — Pinnacle Prime French Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-prime-french-sliding-patio-door-4/) | Wood | 0.26 | 0.12 | 71 |
| [**Pella Corporation** — Reserve Multi-Slide](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-reserve-multi-slide-413914/) | Wood | 0.26 | 0.14 | 69 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Inswing French Door appear below.

### What U-Factor and SHGC range does Marvin Ultimate Wood Inswing French Door achieve?

Across 1,164 tested NFRC glazing configurations, Marvin Ultimate Wood Inswing French Door with Wood framing and Hinged Patio French Door (DDFR) style reaches a 0.26 minimum U-Factor and 0.10-0.24 SHGC band. It places #233 among 268 Door series—more insulating than 7.5%.

### Does Marvin Ultimate Wood Inswing French Door qualify for the ENERGY STAR Northern Zone?

With a 0.26 minimum U-Factor, Marvin Ultimate Wood Inswing French Door cannot satisfy prescriptive <= 0.22 Northern targets, yet 216 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### How do you calculate winter heat conduction for Marvin Ultimate Wood Inswing French Door?

At U 0.26, a standard 3x5 ft (15 sq ft) Ultimate Wood Inswing French Door opening transfers 156.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +24.0 BTU/hr difference.

### What are the practical limitations of specifying Ultimate Wood Inswing French Door?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Inswing French Door options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### What Southern ENERGY STAR v7.0 options exist in Ultimate Wood Inswing French Door?

Warm-climate homeowners have 1,152 Southern-approved options within Ultimate Wood Inswing French Door spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 1,164 Ultimate Wood Inswing French Door configurations ENERGY STAR Most Efficient?

No. Zero of the 1,164 configurations in Marvin Ultimate Wood Inswing French Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### Can homeowners claim Form 5695 credits on Marvin Ultimate Wood Inswing French Door in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do you cross-check NFRC MAR and product line MAR-N-393 on delivery?

Match the NFRC thermal sticker for code MAR and line MAR-N-393 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Inswing French Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)