title: "Marvin Vivid Double Hung / Insert Specs (U 0.24)"
url: https://ela-ecolandscapingassn.org/windows/models/marvin-vivid-double-hung-insert-413658/
description: "Marvin Vivid Double Hung / Insert (MAR-N-493, Double Hung, Fiberglass): U-Factor 0.24-0.32, SHGC 0.11-0.46, 788 options across 4 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-493

# Marvin — Vivid Double Hung / Insert · Double Hung

Across 105 Marvin certified families, Vivid Double Hung / Insert supplies 788 Double Hung configurations starting at 0.24 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.46 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.11-0.46

- **Certified Options** : 788

- **Category Standing** : #1,034 of 1,352

## How does Marvin Vivid Double Hung / Insert compare thermally against Window peers?

Marvin Vivid Double Hung / Insert achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Marvin Vivid Double Hung / Insert at rank #1,034 of 1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.46 band.

Mapping NFRC SHGC values (0.11 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 62 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors MAR to 2026-09-01 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 788 certified glazing combinations for Vivid Double Hung / Insert (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 62 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 128 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 371 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 692 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Revive Clad Pocket Awning](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-clad-pocket-awning-414450/) | Wood | 0.24 | 0.15 | 782 |
| [**YKK AP America, Inc.** — Style View Single Slider](https://ela-ecolandscapingassn.org/windows/models/ykk-ap-america-inc-style-view-single-slider-414480/) | Vinyl | 0.24 | 0.19 | 803 |
| [**Atrium Companies, Inc.** — 450/455/460/465 DH](https://ela-ecolandscapingassn.org/windows/models/atrium-companies-inc-450-455-460-465-dh-412876/) | Vinyl | 0.24 | 0.15 | 805 |
| [**Windsor Windows and Doors** — Revive Clad Pocket Casement](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-revive-clad-pocket-casement-414446/) | Wood | 0.24 | 0.15 | 805 |
| [**JELD-WEN, inc.** — Custom Clad Epic Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-custom-clad-epic-double-hung-picture-413372/) | Wood | 0.24 | 0.10 | 755 |

## What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [Ultimate Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

U-Factor 0.13–0.32 · 34,184 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-direct-glaze-rectangle-polygon-413620/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Rectangle / Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

U-Factor 0.13–0.32 · 13,899 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-rectangle-polygon-413622/)

Picture WindowMin U 0.13

### [Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

U-Factor 0.13–0.32 · 8,590 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

U-Factor 0.13–0.32 · 2,649 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-413556/)

Double HungMin U 0.13

### [Ultimate Wood Double Hung / Single Hung Magnum](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

U-Factor 0.13–0.32 · 2,481 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-double-hung-single-hung-magnum-413578/)

Picture WindowMin U 0.14

### [Modern Direct Glaze Rectangle/Polygon](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

U-Factor 0.14–0.32 · 2,988 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/marvin-modern-direct-glaze-rectangle-polygon-413635/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Vivid Double Hung / Insert appear below.

### What thermal performance numbers separate Marvin Vivid Double Hung / Insert from peers?

Built with Fiberglass framing in Double-Hung (VSDH) style, Marvin Vivid Double Hung / Insert offers 788 Version 7.0 configurations from U 0.24 up to 0.32, posting +0.04 against the Window median of 0.20 with 0 Most Efficient picks.

### Does Marvin Vivid Double Hung / Insert qualify for the ENERGY STAR Northern Zone?

Because Vivid Double Hung / Insert starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 62 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

### How do you calculate winter heat conduction for Marvin Vivid Double Hung / Insert?

Using NFRC MAR U-Factor 0.24, a 15 sq ft Double-Hung (VSDH) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

### What are the practical limitations of specifying Vivid Double Hung / Insert?

Do not specify Vivid Double Hung / Insert without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Vivid Double Hung / Insert options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Can you install Marvin Vivid Double Hung / Insert in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 692 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Vivid Double Hung / Insert, while total line SHGC reaches 0.46 in colder packages.

### Does Vivid Double Hung / Insert carry EPA Most Efficient certification across its lineup?

Vivid Double Hung / Insert holds zero Most Efficient entries across its 788 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### What 2026 federal tax credit and Lead RRP rules apply to Vivid Double Hung / Insert?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Vivid Double Hung / Insert glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-493, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Vivid Double Hung / Insert come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)