title: "Mercury Excelum EOS\\EOS+\\ICON Double Hung Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-double-hung-413718/
description: "Mercury Excelum EOS\\EOS+\\ICON Double Hung (MEX-M-22, Double Hung, Vinyl): U-Factor 0.17-0.31, SHGC 0.16-0.24, 148 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC MEX · Product Line MEX-M-22 ENERGY STAR Most Efficient Eligible

# Mercury Excelum, Inc. — EOS\EOS+\ICON Double Hung · Double Hung

Mercury Excelum, Inc. engineered the EOS\EOS+\ICON Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 148 glass-spacer combinations from 0.17 to 0.31 U-Factor and 0.16 to 0.24 SHGC. Relative to other Vinyl models tracked under NFRC MEX, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.16-0.24

- **Certified Options** : 148

- **Category Standing** : #362 of 1,352

## How does Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung compare thermally against Window peers?

Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.16-0.24 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 72 configurations meet ENERGY STAR Most Efficient criteria while 68 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-05 licensing and 2025-08-05 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 148 certified glazing combinations for EOS\EOS+\ICON Double Hung (NFRC MEX) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 68 packages (24 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 80 packages (48 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 106 packages (40 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 136 packages (64 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**NT Window, Inc.** — A100-Awning](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-a100-awning-413846/) | Vinyl | 0.17 | 0.11 | 148 |
| [**Lindsay Windows** — ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-pinnacle-healthy-fixe/) | Vinyl | 0.17 | 0.18 | 156 |
| [**NT Window, Inc.** — C100/G100-Casement](https://ela-ecolandscapingassn.org/windows/models/nt-window-inc-c100-g100-casement-413845/) | Vinyl | 0.17 | 0.11 | 156 |
| [**Thompson Creek Window Company** — 7900 Fixed](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-fixed-414148/) | Vinyl | 0.17 | 0.18 | 134 |
| [**Mathews Brothers Company** — Sanford Hills Tripane Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-tripane-fixed-casement-413666/) | Vinyl | 0.17 | 0.21 | 130 |

## What other certified series does Mercury Excelum, Inc. produce?

Compare other active Mercury Excelum, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [EOS\EOS+\ICON Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-fixed-casement-413722/)

U-Factor 0.15–0.32 · 179 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-fixed-casement-413722/)

Awning (Projected)Min U 0.16

### [EOS\EOS+\ICON Awning](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-awning-413721/)

U-Factor 0.16–0.29 · 166 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-awning-413721/)

Casement WindowsMin U 0.16

### [EOS\EOS+\ICON Casement](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-casement-413720/)

U-Factor 0.16–0.29 · 190 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-casement-413720/)

Picture WindowMin U 0.16

### [EOS\EOS+\ICON Picture Window](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-picture-window-413719/)

U-Factor 0.16–0.32 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-picture-window-413719/)

Double SliderMin U 0.18

### [EOS\EOS+\ICON Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-horizontal-slider-413723/)

U-Factor 0.18–0.31 · 78 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-horizontal-slider-413723/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung appear below.

### How well does EOS\EOS+\ICON Double Hung by Mercury Excelum, Inc. insulate relative to Window benchmarks?

Across 148 tested NFRC glazing configurations, Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.17 minimum U-Factor and 0.16-0.24 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

### Which glazing options in Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung meet Northern climate limits?

Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung supplies 68 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.31, so inspect the NFRC order sheet before purchase.

### How do you calculate winter heat conduction for Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung?

At U 0.17, a standard 3x5 ft (15 sq ft) EOS\EOS+\ICON Double Hung opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

### What are the practical limitations of specifying EOS\EOS+\ICON Double Hung?

Do not specify EOS\EOS+\ICON Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on EOS\EOS+\ICON Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does EOS\EOS+\ICON Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 136 EOS\EOS+\ICON Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.16 rather than higher 0.24 glass.

### Are all 148 EOS\EOS+\ICON Double Hung configurations ENERGY STAR Most Efficient?

No. Exactly 72 of 148 configurations (48.6%) earn ENERGY STAR Most Efficient status in EOS\EOS+\ICON Double Hung; the remaining standard v7.0 options pass base zone limits only.

### Can homeowners claim Form 5695 credits on Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Mercury Excelum, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### What permanent glass etch marks verify EOS\EOS+\ICON Double Hung after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line MEX-M-22 and NFRC ID MEX before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Mercury Excelum, Inc. EOS\EOS+\ICON Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)