title: "Mercury Excelum EOS\\EOS+\\ICON Horizontal Slider Specs"
url: https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-horizontal-slider-413723/
description: "Mercury Excelum EOS\\EOS+\\ICON Horizontal Slider (MEX-M-27, Double Slider, Vinyl): U-Factor 0.18-0.31, SHGC 0.16-0.24, 78 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC MEX · Product Line MEX-M-27 ENERGY STAR Most Efficient Eligible

# Mercury Excelum, Inc. — EOS\EOS+\ICON Horizontal Slider · Double Slider

With a minimum U-Factor of 0.18—-0.02 compared against the 0.20 Window median—Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider spans 78 tested options across Northern, North-Central, South-Central, Southern up to 0.31 U-Factor. Carrying NFRC CPD code MEX, the Vinyl assembly includes 36 ENERGY STAR Most Efficient packages (46.2% of line) and offers SHGC packages between 0.16 and 0.24.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.16-0.24

- **Certified Options** : 78

- **Category Standing** : #477 of 1,352

## How does Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider compare thermally against Window peers?

Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), EOS\EOS+\ICON Horizontal Slider reaches 0.18 on its lowest-conductivity package — #354 of 1,009 in Vinyl, tied with 74 others at 0.18, more insulating than 57.6% of Vinyl lines, top 42.4% (-0.01 vs Vinyl peers). Pairing NFRC ID MEX across multi-pane fills shifts U-Factor from 0.31 down toward 0.18.

Regional qualification covers Northern, North-Central, South-Central, Southern. 36 configurations meet ENERGY STAR Most Efficient criteria while 28 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-09-05 and v7.0 data certification on 2025-08-05. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 78 certified glazing combinations for EOS\EOS+\ICON Horizontal Slider (NFRC MEX) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 28 packages (10 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 40 packages (24 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 54 packages (22 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 72 packages (34 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Ideal Window Manufacturing** — Professional, Perfect Fit, Majestic, Lifescape, Platinum Double Hung](https://ela-ecolandscapingassn.org/windows/models/ideal-window-manufacturing-professional-perfect-fit-majestic-lifesca/) | Vinyl | 0.18 | 0.14 | 80 |
| [**National Vinyl, LLC** — TG/NW3/Destiny/Duratrust/Clarion/Sentinel Casement](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-casemen/) | Vinyl | 0.18 | 0.18 | 75 |
| [**Wallside Windows** — PW - Picture Window](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pw-picture-window-414319/) | Vinyl | 0.18 | 0.19 | 82 |
| [**National Vinyl, LLC** — TG/NW3/Destiny/Duratrust/Clarion/Sentinel Awning](https://ela-ecolandscapingassn.org/windows/models/national-vinyl-llc-tg-nw3-destiny-duratrust-clarion-sentinel-awning/) | Vinyl | 0.18 | 0.18 | 73 |
| [**Vector Windows** — Envision Double Glider](https://ela-ecolandscapingassn.org/windows/models/vector-windows-envision-double-glider-414031/) | Vinyl | 0.18 | 0.16 | 69 |

## What other certified series does Mercury Excelum, Inc. produce?

Compare other active Mercury Excelum, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [EOS\EOS+\ICON Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-fixed-casement-413722/)

U-Factor 0.15–0.32 · 179 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-fixed-casement-413722/)

Awning (Projected)Min U 0.16

### [EOS\EOS+\ICON Awning](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-awning-413721/)

U-Factor 0.16–0.29 · 166 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-awning-413721/)

Casement WindowsMin U 0.16

### [EOS\EOS+\ICON Casement](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-casement-413720/)

U-Factor 0.16–0.29 · 190 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-casement-413720/)

Picture WindowMin U 0.16

### [EOS\EOS+\ICON Picture Window](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-picture-window-413719/)

U-Factor 0.16–0.32 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-picture-window-413719/)

Double HungMin U 0.17

### [EOS\EOS+\ICON Double Hung](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-double-hung-413718/)

U-Factor 0.17–0.31 · 148 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-double-hung-413718/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider appear below.

### How efficient is Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider compared with peer Window models?

EPA ENERGY STAR v7.0 records 78 configurations for Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.20 Window median. Only 36 options earn Most Efficient status.

### How does Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 28 compliant Northern packages inside EOS\EOS+\ICON Horizontal Slider, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.

### What BTU/hr heat transfer results from EOS\EOS+\ICON Horizontal Slider's 0.18 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 108.0 BTU/hr on EOS\EOS+\ICON Horizontal Slider's lowest-U package (0.18), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.

### Who should NOT choose Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider for a residential project?

Do not specify EOS\EOS+\ICON Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on EOS\EOS+\ICON Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does EOS\EOS+\ICON Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 72 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider, while total line SHGC reaches 0.24 in colder packages.

### How many Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider variants earn ENERGY STAR Most Efficient?

EPA lists 36 Most Efficient options (46.2% share) inside Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider, out of 78 total Version 7.0 entries.

### How do the 25C sunset and pre-1978 Lead RRP rules affect EOS\EOS+\ICON Horizontal Slider?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify EOS\EOS+\ICON Horizontal Slider glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line MEX-M-27 and NFRC ID MEX before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Mercury Excelum, Inc. EOS\EOS+\ICON Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)