title: "MGM Industries 4600 Picture Window / Transom Specs"
url: https://ela-ecolandscapingassn.org/windows/models/mgm-industries-4600-picture-window-transom-413726/
description: "MGM Industries 4600 Picture Window / Transom (MGM-A-21, Picture Window, Vinyl): U-Factor 0.21-0.30, SHGC 0.19-0.32, 57 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC MGM · Product Line MGM-A-21 ENERGY STAR Most Efficient Eligible

# MGM Industries — 4600 Picture Window / Transom · Picture Window

MGM Industries engineered the 4600 Picture Window / Transom Picture Window line for Northern, North-Central, South-Central, Southern, certifying 57 glass-spacer combinations from 0.21 to 0.30 U-Factor and 0.19 to 0.32 SHGC. Relative to other Vinyl models tracked under NFRC MGM, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.19-0.32

- **Certified Options** : 57

- **Category Standing** : #742 of 1,352

## How does MGM Industries 4600 Picture Window / Transom compare thermally against Window peers?

MGM Industries 4600 Picture Window / Transom achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 4600 Picture Window / Transom is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.30.

Mapping NFRC SHGC values (0.19 to 0.32) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 13 configurations meet ENERGY STAR Most Efficient criteria while 30 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-11-08 and cert timestamp 2024-04-12.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 57 certified glazing combinations for 4600 Picture Window / Transom (NFRC MGM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 30 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 45 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 31 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 35 packages (13 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Wallside Windows** — ESTDS Double Slider](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-estds-double-slider-414317/) | Vinyl | 0.21 | 0.18 | 64 |
| [**Vytex Corporation** — Fortis Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-fortis-double-hung-414299/) | Vinyl | 0.21 | 0.16 | 68 |
| [**Wallside Windows** — SDH Double Hung](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sdh-double-hung-414318/) | Vinyl | 0.21 | 0.18 | 72 |
| [**Vinyl Kraft, Inc.** — TrustGard Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trustgard-horizontal-slider-414225/) | Vinyl | 0.21 | 0.17 | 76 |
| [**Vytex Corporation** — 8000 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8000-fixed-414288/) | Vinyl | 0.21 | 0.21 | 36 |

## What other certified series does MGM Industries produce?

Compare other active MGM Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [6010 Picture Window](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-picture-window-413725/)

U-Factor 0.21–0.32 · 387 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-picture-window-413725/)

Picture WindowMin U 0.21

### [6010 Sloped Sill Picture Window](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-sloped-sill-picture-window-413730/)

U-Factor 0.21–0.32 · 381 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-sloped-sill-picture-window-413730/)

Picture WindowMin U 0.22

### [8017 Sloped Sill Picture](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-8017-sloped-sill-picture-413728/)

U-Factor 0.22–0.30 · 75 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-8017-sloped-sill-picture-413728/)

Sliding Patio DoorMin U 0.22

### [9000/9050 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-9000-9050-sliding-glass-door-413727/)

U-Factor 0.22–0.28 · 1,317 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-9000-9050-sliding-glass-door-413727/)

Single HungMin U 0.23

### [6010/6060 Single Hung](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-6060-single-hung-413724/)

U-Factor 0.23–0.31 · 641 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-6060-single-hung-413724/)

Single SliderMin U 0.24

### [6010 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-horizontal-slider-413729/)

U-Factor 0.24–0.31 · 382 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-horizontal-slider-413729/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MGM Industries 4600 Picture Window / Transom appear below.

### Where does MGM Industries 4600 Picture Window / Transom stand thermally among ENERGY STAR Window lines?

Across 57 tested NFRC glazing configurations, MGM Industries 4600 Picture Window / Transom with Vinyl framing and Fixed Window (FIXD) style reaches a 0.21 minimum U-Factor and 0.19-0.32 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.

### Can homeowners install 4600 Picture Window / Transom in cold Northern ENERGY STAR counties?

Cold-climate buyers get 30 compliant Northern packages inside 4600 Picture Window / Transom, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.30 options.

### What conductive BTU/hr difference separates 4600 Picture Window / Transom from the 0.22 Northern rule?

At U 0.21, a standard 3x5 ft (15 sq ft) 4600 Picture Window / Transom opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

### Which situations make 4600 Picture Window / Transom the wrong window or door choice?

Do not specify 4600 Picture Window / Transom without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 4600 Picture Window / Transom options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in 4600 Picture Window / Transom?

Warm-climate homeowners have 35 Southern-approved options within 4600 Picture Window / Transom spanning SHGC down to 0.19. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### What glazing share inside 4600 Picture Window / Transom qualifies as Most Efficient?

Only 13 options out of 57 (22.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in MGM Industries 4600 Picture Window / Transom, usually requiring triple-pane or upgraded Low-E coatings.

### What federal compliance checks govern 2026 4600 Picture Window / Transom window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on 4600 Picture Window / Transom?

Inspectors match the temporary NFRC sticker (U 0.21-0.30, SHGC 0.19-0.32) against permit drawings for line MGM-A-21. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MGM Industries 4600 Picture Window / Transom come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)