---
title: "MGM Industries 6010 Picture Window Specs (U 0.21)"
url: https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-picture-window-413725/
description: "MGM Industries 6010 Picture Window (MGM-A-6, Picture Window, Vinyl): U-Factor 0.21-0.32, SHGC 0.14-0.31, 387 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC MGM · Product Line MGM-A-6 ENERGY STAR Most Efficient Eligible

# MGM Industries — 6010 Picture Window · Picture Window

MGM Industries engineered the 6010 Picture Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 387 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.14 to 0.31 SHGC. Relative to other Vinyl models tracked under NFRC MGM, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.14-0.31

- **Certified Options** : 387

- **Category Standing** : #742 of 1,352

## How does MGM Industries 6010 Picture Window compare thermally against Window peers?

MGM Industries 6010 Picture Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 6010 Picture Window spans 387 NFRC test records (MGM), ranking #742 of 1,352 Window families (tied with 88 others at 0.21, more insulating than 38.6% of Window lines). Its 0.21 thermal floor compares at +0.02 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.14 to 0.31) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 39 configurations meet ENERGY STAR Most Efficient criteria while 64 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-11-08 and v7.0 data certification on 2026-05-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 387 certified glazing combinations for 6010 Picture Window (NFRC MGM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 64 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 224 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 270 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 299 packages (39 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Next Dimension Pro Direct Set / Radius](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-pro-direct-set-radius-41442/) | Vinyl | 0.21 | 0.18 | 303 |
| [**Earthwise Group, LLC** — 143.000/145.000/343.000/443.000/643.000 Picture Window](https://ela-ecolandscapingassn.org/windows/models/earthwise-group-llc-143-000-145-000-343-000-443-000-643-000-picture/) | Vinyl | 0.21 | 0.14 | 299 |
| [**Windsor Windows and Doors** — Next Dimension Pro Brickmould Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-pro-brickmould-direct-set-4/) | Vinyl | 0.21 | 0.18 | 298 |
| [**A Window, Inc.** — SL3 Series Picture Window (15997 Frame)](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-sl3-series-picture-window-15997-frame-413087/) | Vinyl | 0.21 | 0.18 | 477 |
| [**Anlin Industries** — Monte Verde Fixed](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-monte-verde-fixed-413035/) | Vinyl | 0.21 | 0.14 | 296 |

## What other certified series does MGM Industries produce?

Compare other active MGM Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [4600 Picture Window / Transom](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-4600-picture-window-transom-413726/)

U-Factor 0.21–0.30 · 57 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-4600-picture-window-transom-413726/)

Picture WindowMin U 0.21

### [6010 Sloped Sill Picture Window](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-sloped-sill-picture-window-413730/)

U-Factor 0.21–0.32 · 381 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-sloped-sill-picture-window-413730/)

Picture WindowMin U 0.22

### [8017 Sloped Sill Picture](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-8017-sloped-sill-picture-413728/)

U-Factor 0.22–0.30 · 75 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-8017-sloped-sill-picture-413728/)

Sliding Patio DoorMin U 0.22

### [9000/9050 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-9000-9050-sliding-glass-door-413727/)

U-Factor 0.22–0.28 · 1,317 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-9000-9050-sliding-glass-door-413727/)

Single HungMin U 0.23

### [6010/6060 Single Hung](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-6060-single-hung-413724/)

U-Factor 0.23–0.31 · 641 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-6060-single-hung-413724/)

Single SliderMin U 0.24

### [6010 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-horizontal-slider-413729/)

U-Factor 0.24–0.31 · 382 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-6010-horizontal-slider-413729/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MGM Industries 6010 Picture Window appear below.

### How well does 6010 Picture Window by MGM Industries insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 387 configurations for MGM Industries 6010 Picture Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 39 options earn Most Efficient status.

### How does MGM Industries 6010 Picture Window satisfy Version 7.0 Northern criteria?

Yes, 64 packages satisfy Northern ENERGY STAR Version 7.0 rules in 6010 Picture Window. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How much winter heat loss does 6010 Picture Window conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 6010 Picture Window at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip MGM Industries 6010 Picture Window and compare alternatives?

Do not specify 6010 Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 6010 Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does 6010 Picture Window meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 299 6010 Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.31 glass.

### How many MGM Industries 6010 Picture Window variants earn ENERGY STAR Most Efficient?

Only 39 options out of 387 (10.1%) meet tighter Most Efficient U-Factor and SHGC thresholds in MGM Industries 6010 Picture Window, usually requiring triple-pane or upgraded Low-E coatings.

### What 2026 federal tax credit and Lead RRP rules apply to 6010 Picture Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 6010 Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered MGM Industries 6010 Picture Window units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line MGM-A-6 and NFRC ID MGM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MGM Industries 6010 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
