description: "MI Windows and Doors SR SH | DH SP Vinyl Fixed Specialty Window (MEI-A-264, Picture Window, Vinyl): U-Factor 0.17-0.31, SHGC 0.09-0.57, 4152 options across."
---

Window · Vinyl Frame NFRC MEI · Product Line MEI-A-264 ENERGY STAR Most Efficient Eligible

# MI Windows and Doors, LLC — SR SH | DH SP Vinyl Fixed Specialty Window · Picture Window

MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 4,152 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.57.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.09-0.57

- **Certified Options** : 4,152

- **Category Standing** : #362 of 1,352

## How does MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window compare thermally against Window peers?

MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), SR SH | DH SP Vinyl Fixed Specialty Window reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID MEI across multi-pane fills shifts U-Factor from 0.31 down toward 0.17.

Regional qualification covers Northern, North-Central, South-Central, Southern. 1,227 configurations meet ENERGY STAR Most Efficient criteria while 1,555 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2026-07-23.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,152 certified glazing combinations for SR SH | DH SP Vinyl Fixed Specialty Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 1,555 packages (305 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 2,833 packages (645 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 2,453 packages (476 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,814 packages (1,008 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Amsco Windows** — VZ1 Hampton PM Fixed](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-pm-fixed-412900/) | Vinyl | 0.17 | 0.11 | 2,764 |
| [**Vinylmax LLC** — DSA4 Double Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dsa4-double-slider-414265/) | Vinyl | 0.17 | 0.14 | 2,757 |
| [**Sierra Pacific Windows** — Vinyl Direct Set](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-direct-set-414078/) | Vinyl | 0.17 | 0.12 | 2,077 |
| [**Wincore Window Company, LLC** — 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin-414335/) | Vinyl | 0.17 | 0.08 | 6,256 |
| [**Wincore Window Company, LLC** — 7700, 9900 Basement Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-7700-9900-basement-window-414340/) | Vinyl | 0.17 | 0.08 | 6,256 |

## What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.12

### [9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-9660-9770-polyvinyl-chloride-pvc-fixed-dire/)

U-Factor 0.12–0.32 · 8,307 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-9660-9770-polyvinyl-chloride-pvc-fixed-dire/)

Picture WindowMin U 0.13

### [9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-9660-9770-polyvinyl-chloride-pvc-fixed-sash/)

U-Factor 0.13–0.32 · 6,920 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-9660-9770-polyvinyl-chloride-pvc-fixed-sash/)

TransomMin U 0.14

### [1615T Polyvinyl Chloride (PVC) Transom](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1615t-polyvinyl-chloride-pvc-transom-413693/)

U-Factor 0.14–0.31 · 3,234 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1615t-polyvinyl-chloride-pvc-transom-413693/)

Picture WindowMin U 0.14

### [3075/3065 Direct Set Picture Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-3075-3065-direct-set-picture-window-413710/)

U-Factor 0.14–0.32 · 35,308 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-3075-3065-direct-set-picture-window-413710/)

Picture WindowMin U 0.14

### [SR CASE PW Vinyl Fixed Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-sr-case-pw-vinyl-fixed-window-413698/)

U-Factor 0.14–0.31 · 5,254 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-sr-case-pw-vinyl-fixed-window-413698/)

Picture WindowMin U 0.15

### [1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1650-polyvinyl-chloride-pvc-fixed-direct-se/)

U-Factor 0.15–0.32 · 11,774 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1650-polyvinyl-chloride-pvc-fixed-direct-se/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window appear below.

### Where does MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window stand thermally among ENERGY STAR Window lines?

Testing puts MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window at rank #362 of 1,352 Window entries with U 0.17 to 0.31 across 4,152 configurations. Solar heat gain ranges between 0.09 and 0.57 across Northern, North-Central, South-Central, Southern.

### Can homeowners install SR SH | DH SP Vinyl Fixed Specialty Window in cold Northern ENERGY STAR counties?

MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window supplies 1,555 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.31, so inspect the NFRC order sheet before purchase.

### What conductive BTU/hr difference separates SR SH | DH SP Vinyl Fixed Specialty Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on SR SH | DH SP Vinyl Fixed Specialty Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### Can you install MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window in Southern or South-Central zones?

Warm-climate homeowners have 2,814 Southern-approved options within SR SH | DH SP Vinyl Fixed Specialty Window spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 4,152 SR SH | DH SP Vinyl Fixed Specialty Window configurations ENERGY STAR Most Efficient?

Only 1,227 options out of 4,152 (29.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window, usually requiring triple-pane or upgraded Low-E coatings.

### What federal compliance checks govern 2026 SR SH | DH SP Vinyl Fixed Specialty Window window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on SR SH | DH SP Vinyl Fixed Specialty Window?

Verify NFRC ID MEI and series MEI-A-264 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC SR SH | DH SP Vinyl Fixed Specialty Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)