title: "Milgard Manufacturing 3642/3662 Inswing Patio Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3642-3662-inswing-patio-door-413743/
description: "Milgard Manufacturing 3642/3662 Inswing Patio Door (MIL-A-242, Swinging Entry Door (Single), Fiberglass): U-Factor 0.23-0.28, SHGC 0.12-0.32, 1049 options."
---

Door · Fiberglass Frame NFRC MIL · Product Line MIL-A-242

# Milgard Manufacturing, Inc. — 3642/3662 Inswing Patio Door · Swinging Entry Door (Single)

With a minimum U-Factor of 0.23—+0.02 compared against the 0.21 Door median—Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door spans 1,049 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code MIL, the Fiberglass assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.32.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.12-0.32

- **Certified Options** : 1,049

- **Category Standing** : #162 of 268

## How does Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door compare thermally against Door peers?

Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door standing at #162 of 268 certified Door product series, tied with 36 others at 0.23, more insulating than 26.1% of Door lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 128 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2025-01-30 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,049 certified glazing combinations for 3642/3662 Inswing Patio Door (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 128 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 128 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 1,024 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 1,024 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — Multi-Glide Patio Door - Clad Panels; Thermally Controlled Frame](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-multi-glide-patio-door-clad-panels-thermally-co/) | Fiberglass | 0.23 | 0.10 | 1,161 |
| [**Marvin** — Infinity Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/marvin-infinity-sliding-glass-door-413604/) | Fiberglass | 0.23 | 0.15 | 301 |
| [**Weather Shield Mfg., Inc.** — 8622 Premium / 8623 Contemporary Bi-Fold Door](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8622-premium-8623-contemporary-bi-fold-door-4/) | Wood | 0.23 | 0.10 | 1,008 |
| [**JELD-WEN, inc.** — Siteline Clad Swinging Door](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-swinging-door-413377/) | Wood | 0.23 | 0.11 | 971 |
| [**Sierra Pacific Windows** — Clad Outswing Door](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-outswing-door-414071/) | Wood | 0.23 | 0.06 | 1,159 |

## What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8521T2.8531T2.8571T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

U-Factor 0.13–0.32 · 23,185 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

Picture WindowMin U 0.13

### [8541T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

U-Factor 0.13–0.32 · 37,615 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

Picture WindowMin U 0.14

### [12710 Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

U-Factor 0.14–0.32 · 3,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

Picture WindowMin U 0.14

### [8320T2.8330T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

U-Factor 0.14–0.32 · 22,562 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

Picture WindowMin U 0.14

### [8340T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

U-Factor 0.14–0.32 · 35,182 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

Picture WindowMin U 0.15

### [12330 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

U-Factor 0.15–0.32 · 7,836 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door appear below.

### What U-Factor and SHGC range does Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door achieve?

Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door spans 1,049 certified configurations with U-Factors between 0.23 and 0.28 and SHGC values from 0.12 to 0.32. Ranked #162 of 268 Door families, it carries 0 Most Efficient options.

### How does Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door satisfy Version 7.0 Northern criteria?

With a 0.23 minimum U-Factor, Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door cannot satisfy prescriptive <= 0.22 Northern targets, yet 128 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

### What BTU/hr heat transfer results from 3642/3662 Inswing Patio Door's 0.23 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 3642/3662 Inswing Patio Door at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What homeowner profiles are a poor match for Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 3642/3662 Inswing Patio Door options exceeding U 0.22. Verify whether your municipal code restricts Fiberglass frames in wildfire or historic zones.

### Does 3642/3662 Inswing Patio Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 1,024 Southern-certified options inside Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.32 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Which package tier in 3642/3662 Inswing Patio Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 1,049 3642/3662 Inswing Patio Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What federal compliance checks govern 2026 3642/3662 Inswing Patio Door window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 3642/3662 Inswing Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify 3642/3662 Inswing Patio Door after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line MIL-A-242 and NFRC ID MIL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)