title: "Milgard Manufacturing 3646/3666 Transom Specs (U 0.17)"
url: https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3646-3666-transom-413745/
description: "Milgard Manufacturing 3646/3666 Transom (MIL-A-247, Picture Window, Fiberglass): U-Factor 0.17-0.32, SHGC 0.10-0.52, 3449 options across 4 ENERGY STAR zones."
---

Window · Fiberglass Frame NFRC MIL · Product Line MIL-A-247 ENERGY STAR Most Efficient Eligible

# Milgard Manufacturing, Inc. — 3646/3666 Transom · Picture Window

EPA ENERGY STAR Version 7.0 certifies 3,449 variants inside Milgard Manufacturing, Inc. 3646/3666 Transom, combining Fiberglass frame construction with U-Factors spanning 0.17 to 0.32 and SHGC 0.10 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Fiberglass peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.10-0.52

- **Certified Options** : 3,449

- **Category Standing** : #362 of 1,352

## How does Milgard Manufacturing, Inc. 3646/3666 Transom compare thermally against Window peers?

Milgard Manufacturing, Inc. 3646/3666 Transom achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 3646/3666 Transom is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Fiberglass frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 103 configurations meet ENERGY STAR Most Efficient criteria while 475 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-02-13 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,449 certified glazing combinations for 3646/3666 Transom (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 475 packages (81 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,365 packages (72 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,795 packages (36 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,512 packages (58 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Marvin** — Vivd Casement Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-vivd-casement-picture-413656/) | Fiberglass | 0.17 | 0.07 | 1,802 |
| [**Marvin** — Infinity Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-infinity-double-hung-picture-413570/) | Fiberglass | 0.17 | 0.07 | 695 |
| [**Marvin** — Infinity Insert Double Hung Picture](https://ela-ecolandscapingassn.org/windows/models/marvin-infinity-insert-double-hung-picture-413563/) | Fiberglass | 0.17 | 0.07 | 685 |
| [**Andersen Corporation** — 400 Series Specialty Window - Double Hung Half Circle](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-window-double-hung-half-ci/) | Wood | 0.17 | 0.15 | 2,938 |
| [**Amsco Windows** — VZ1 Hampton PM Fixed](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-pm-fixed-412900/) | Vinyl | 0.17 | 0.11 | 2,764 |

## What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8521T2.8531T2.8571T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

U-Factor 0.13–0.32 · 23,185 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

Picture WindowMin U 0.13

### [8541T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

U-Factor 0.13–0.32 · 37,615 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

Picture WindowMin U 0.14

### [12710 Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

U-Factor 0.14–0.32 · 3,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

Picture WindowMin U 0.14

### [8320T2.8330T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

U-Factor 0.14–0.32 · 22,562 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

Picture WindowMin U 0.14

### [8340T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

U-Factor 0.14–0.32 · 35,182 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

Picture WindowMin U 0.15

### [12330 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

U-Factor 0.15–0.32 · 7,836 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3646/3666 Transom appear below.

### How well does 3646/3666 Transom by Milgard Manufacturing, Inc. insulate relative to Window benchmarks?

Built with Fiberglass framing in Fixed Window (FIXD) style, Milgard Manufacturing, Inc. 3646/3666 Transom offers 3,449 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 103 Most Efficient picks.

### Can homeowners install 3646/3666 Transom in cold Northern ENERGY STAR counties?

Milgard Manufacturing, Inc. 3646/3666 Transom supplies 475 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How does a 3x5 ft 3646/3666 Transom window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip Milgard Manufacturing, Inc. 3646/3666 Transom and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 3646/3666 Transom options exceeding U 0.22. Verify whether your municipal code restricts Fiberglass frames in wildfire or historic zones.

### What Southern ENERGY STAR v7.0 options exist in 3646/3666 Transom?

Exactly 2,512 3646/3666 Transom options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.10 rather than higher 0.52 glass.

### How many Milgard Manufacturing, Inc. 3646/3666 Transom variants earn ENERGY STAR Most Efficient?

No. Exactly 103 of 3,449 configurations (3.0%) earn ENERGY STAR Most Efficient status in 3646/3666 Transom; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 3646/3666 Transom installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify 3646/3666 Transom after sticker removal?

Verify NFRC ID MIL and series MIL-A-247 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3646/3666 Transom come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)