title: "Milgard Manufacturing 3945/3965 Outswing Patio Door Specs"
url: https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-3945-3965-outswing-patio-door-413756/
description: "Milgard Manufacturing 3945/3965 Outswing Patio Door (MIL-A-278, Swinging Entry Door (Single), Fiberglass): U-Factor 0.24-0.28, SHGC 0.12-0.32, 977 options."
---

Door · Fiberglass Frame NFRC MIL · Product Line MIL-A-278

# Milgard Manufacturing, Inc. — 3945/3965 Outswing Patio Door · Swinging Entry Door (Single)

EPA ENERGY STAR Version 7.0 certifies 977 variants inside Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door, combining Fiberglass frame construction with U-Factors spanning 0.24 to 0.28 and SHGC 0.12 to 0.32. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Single family places #199 of 268 among 268 Door families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Fiberglass peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.12-0.32

- **Certified Options** : 977

- **Category Standing** : #199 of 268

## How does Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door compare thermally against Door peers?

Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), 3945/3965 Outswing Patio Door is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Fiberglass frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.28.

Climate coverage for Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 113 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-05-30 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 977 certified glazing combinations for 3945/3965 Outswing Patio Door (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 113 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 113 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 953 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 953 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — A-Series Frenchwood® Hinged Patio Door - Inswing](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-a-series-frenchwood-hinged-patio-door-inswing-4/) | Wood | 0.24 | 0.10 | 535 |
| [**Andersen Corporation** — 400 Series Frenchwood® Hinged Patio Door - Inswing](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-frenchwood-hinged-patio-door-inswing/) | Wood | 0.24 | 0.10 | 488 |
| [**Sierra Pacific Windows** — Wood Patio Slider](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-wood-patio-slider-414063/) | Wood | 0.24 | 0.09 | 233 |
| [**Neuma Door** — Excel Hinged Door](https://ela-ecolandscapingassn.org/windows/models/nan-ya-plastics-corporation-neuma-door-excel-hinged-door-413821/) | Other | 0.24 | 0.03 | 186 |
| [**Weather Shield Mfg., Inc.** — 8723 Next Gen Sliding Patio Door – Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8723-next-gen-sliding-patio-door-direct-set-4/) | Wood | 0.24 | 0.15 | 180 |

## What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8521T2.8531T2.8571T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

U-Factor 0.13–0.32 · 23,185 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

Picture WindowMin U 0.13

### [8541T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

U-Factor 0.13–0.32 · 37,615 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

Picture WindowMin U 0.14

### [12710 Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

U-Factor 0.14–0.32 · 3,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

Picture WindowMin U 0.14

### [8320T2.8330T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

U-Factor 0.14–0.32 · 22,562 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

Picture WindowMin U 0.14

### [8340T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

U-Factor 0.14–0.32 · 35,182 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

Picture WindowMin U 0.15

### [12330 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

U-Factor 0.15–0.32 · 7,836 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door appear below.

### How well does 3945/3965 Outswing Patio Door by Milgard Manufacturing, Inc. insulate relative to Door benchmarks?

Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door spans 977 certified configurations with U-Factors between 0.24 and 0.28 and SHGC values from 0.12 to 0.32. Ranked #199 of 268 Door families, it carries 0 Most Efficient options.

### Is 3945/3965 Outswing Patio Door approved for Northern Zone heating climates?

Prescriptive Northern approval ends at U <= 0.22, above 3945/3965 Outswing Patio Door's 0.24 minimum. However, 113 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### How much winter heat loss does 3945/3965 Outswing Patio Door conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 3945/3965 Outswing Patio Door's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

### Which situations make 3945/3965 Outswing Patio Door the wrong window or door choice?

Do not specify 3945/3965 Outswing Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 3945/3965 Outswing Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does 3945/3965 Outswing Patio Door meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 953 Southern-approved options within 3945/3965 Outswing Patio Door spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### What glazing share inside 3945/3965 Outswing Patio Door qualifies as Most Efficient?

No. Zero of the 977 configurations in Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### What 2026 federal tax credit and Lead RRP rules apply to 3945/3965 Outswing Patio Door?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on 3945/3965 Outswing Patio Door?

Inspectors match the temporary NFRC sticker (U 0.24-0.28, SHGC 0.12-0.32) against permit drawings for line MIL-A-278. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3945/3965 Outswing Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)