title: "Milgard Manufacturing PRAW [MIL-A-262] | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-6410-6411-6430-6470-6410t-6411t-6430t-6470/
description: "Milgard Manufacturing 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning (MIL-A-262, Awning (Projected), Vinyl): U-Factor 0.24-0.32, SHGC 0.09-0.46, 7335."
---

Window · Vinyl Frame NFRC MIL · Product Line MIL-A-262

# Milgard Manufacturing, Inc. — 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning · Awning (Projected)

Milgard Manufacturing, Inc. engineered the 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 7,335 glass-spacer combinations from 0.24 to 0.32 U-Factor and 0.09 to 0.46 SHGC. Relative to other Vinyl models tracked under NFRC MIL, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.24

- **SHGC Range** : 0.09-0.46

- **Certified Options** : 7,335

- **Category Standing** : #1,034 of 1,352

## How does Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning compare thermally against Window peers?

Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 240 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors MIL to 2026-03-12 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,335 certified glazing combinations for 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 240 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 1,547 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 4,534 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 6,821 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Wincore Window Company, LLC** — 400, 500, 5400 Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-400-500-5400-double-hung-window-414331/) | Vinyl | 0.24 | 0.12 | 5,842 |
| [**JELD-WEN, inc.** — Builders Vinyl (V-2500) Side Load Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-builders-vinyl-v-2500-side-load-single-hung-413346/) | Vinyl | 0.24 | 0.13 | 8,836 |
| [**JELD-WEN, inc.** — Builders Vinyl (V-2500) Tilt Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-builders-vinyl-v-2500-tilt-single-hung-413347/) | Vinyl | 0.24 | 0.14 | 5,460 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 43-06 / 43-17 Single Slider](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-43-06-43-17-single-s/) | Vinyl | 0.24 | 0.08 | 4,149 |
| [**Simonton Building Products, Inc. - Simonton Windows** — 43-06 / 43-17 Single Hung](https://ela-ecolandscapingassn.org/windows/models/simonton-building-products-inc-simonton-windows-43-06-43-17-single-h/) | Vinyl | 0.24 | 0.11 | 4,076 |

## What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8521T2.8531T2.8571T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

U-Factor 0.13–0.32 · 23,185 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

Picture WindowMin U 0.13

### [8541T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

U-Factor 0.13–0.32 · 37,615 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

Picture WindowMin U 0.14

### [12710 Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

U-Factor 0.14–0.32 · 3,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

Picture WindowMin U 0.14

### [8320T2.8330T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

U-Factor 0.14–0.32 · 22,562 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

Picture WindowMin U 0.14

### [8340T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

U-Factor 0.14–0.32 · 35,182 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

Picture WindowMin U 0.15

### [12330 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

U-Factor 0.15–0.32 · 7,836 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning appear below.

### How efficient is Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning compared with peer Window models?

Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning spans 7,335 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.09 to 0.46. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

### Which glazing options in Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning meet Northern climate limits?

Because 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 240 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

### How does a 3x5 ft 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### How many 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning glazing packages pass Southern solar-heat rules?

Exactly 6,821 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.46 glass.

### Does 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning carry EPA Most Efficient certification across its lineup?

All 7,335 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Do 2026 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.09-0.46) against permit drawings for line MIL-A-262. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 6410/6411/6430/6470/6410T/6411T/6430T/6470T Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)