Window · Vinyl Frame NFRC MIL · Product Line MIL-A-268 ENERGY STAR Most Efficient Eligible

# Milgard Manufacturing, Inc. — 8240 Single Hung · Single Hung

Milgard Manufacturing, Inc. 8240 Single Hung is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.18 across 8,937 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #477 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.48.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.09-0.48

- **Certified Options** : 8,937

- **Category Standing** : #477 of 1,352

## How does Milgard Manufacturing, Inc. 8240 Single Hung compare thermally against Window peers?

Milgard Manufacturing, Inc. 8240 Single Hung achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Milgard Manufacturing, Inc. 8240 Single Hung at rank #477 of 1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.48 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 178 configurations meet ENERGY STAR Most Efficient criteria while 529 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2025-02-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8,937 certified glazing combinations for 8240 Single Hung (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 529 packages (69 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,970 packages (84 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 4,800 packages (58 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 8,054 packages (149 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**PGT Industries** — DH5460/5560](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-dh5460-5560-413920/) | Vinyl | 0.18 | 0.08 | 6,757 |
| [**JELD-WEN, inc.** — Premium Vinyl (V-4500) Tilt Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-vinyl-v-4500-tilt-single-hung-413385/) | Vinyl | 0.18 | 0.12 | 11,430 |
| [**Ply Gem Window Group** — Pro Series Classic Sidelite/Transom](https://ela-ecolandscapingassn.org/windows/models/ply-gem-window-group-pro-series-classic-sidelite-transom-413962/) | Vinyl | 0.18 | 0.12 | 5,388 |
| [**DRUTEX S.A.** — IGLO ENERGY Classic Transom](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-classic-transom-413152/) | Vinyl | 0.18 | 0.03 | 4,044 |
| [**Vinylmax LLC** — CA55/CA74 Casement](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-casement-414257/) | Vinyl | 0.18 | 0.13 | 3,415 |

## What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [8521T2.8531T2.8571T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

U-Factor 0.13–0.32 · 23,185 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8521t2-8531t2-8571t2-casement-fixed-413773/)

Picture WindowMin U 0.13

### [8541T2 Casement Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

U-Factor 0.13–0.32 · 37,615 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8541t2-casement-fixed-413778/)

Picture WindowMin U 0.14

### [12710 Fixed](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

U-Factor 0.14–0.32 · 3,568 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12710-fixed-413789/)

Picture WindowMin U 0.14

### [8320T2.8330T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

U-Factor 0.14–0.32 · 22,562 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8320t2-8330t2-picture-window-413774/)

Picture WindowMin U 0.14

### [8340T2 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

U-Factor 0.14–0.32 · 35,182 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-8340t2-picture-window-413775/)

Picture WindowMin U 0.15

### [12330 Picture Window](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

U-Factor 0.15–0.32 · 7,836 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/milgard-manufacturing-inc-12330-picture-window-413787/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 8240 Single Hung appear below.

### Where does Milgard Manufacturing, Inc. 8240 Single Hung stand thermally among ENERGY STAR Window lines?

Testing puts Milgard Manufacturing, Inc. 8240 Single Hung at rank #477 of 1,352 Window entries with U 0.18 to 0.32 across 8,937 configurations. Solar heat gain ranges between 0.09 and 0.48 across Northern, North-Central, South-Central, Southern.

### Does Milgard Manufacturing, Inc. 8240 Single Hung qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 529 8240 Single Hung packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from 8240 Single Hung's 0.18 minimum U-Factor?

At U 0.18, a standard 3x5 ft (15 sq ft) 8240 Single Hung opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

### What are the practical limitations of specifying 8240 Single Hung?

Do not specify 8240 Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 8240 Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in 8240 Single Hung?

Exactly 8,054 8240 Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.48 glass.

### What glazing share inside 8240 Single Hung qualifies as Most Efficient?

Not every package qualifies: 178 of 8,937 8240 Single Hung glazing builds earn Most Efficient recognition (2.0%), while other variants sit on the standard Version 7.0 tier.

### What federal compliance checks govern 2026 8240 Single Hung window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered Milgard Manufacturing, Inc. 8240 Single Hung units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line MIL-A-268 and NFRC ID MIL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 8240 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)